Included in the box are 4 wheels, a handle and screws to install the wheels and handle. You will need a 1/4” nut driver and a Phillips screw driver. The unit has a low/off/high switch located on the backside of the unit. As each home has differences of size, occupancy, location, infiltration rates and homeowner needs, it is hard to estimate when the collectors will need to be changed. Because of the way air moves through the TFPC, the collectors are divided into 3 separate sections. Collectors

heruntergeladen wurde: 3   Dateigröße: 99 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

If they do not operate continuously, then interlocking them electrically with the TFP is acceptable. Consult a certified electrician. ATTENTION The TFP can be installed in several different ways. Please read all suggested methods before attempting installation. Electrical The TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch. C US * LEAVE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratings and dimensions are subject to

heruntergeladen wurde: 2   Dateigröße: 99 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

(Fig. 3) MOUNTING 1. Locate mounting bolts (4) on side of TFP cabinet for vertical hanging (Fig. 3) and remove. 2. Measure distance between the bolts and mark it on the floor/header joist where the TFP is to be hung. 3. Fasten hanging straps to floor joists using wide head nails or screws with washers. 4. Insert hanging bolts through prepunched holes in straps and lift TFP into position. Tighten and secure bolts. DUCTING 1. Install (2) 7” port collars (provided) on TFP cabinet with (8) 8/32” X 3

heruntergeladen wurde: 0   Dateigröße: 149 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

The two cores are arranged for highly efficient counter current airflow. MOTORS AND BLOWERS Each air stream has one centrifugal blower driven by a common ECM motor. 5 speed fan operation. 120 VAC, 1.4 Amps. FILTERS Washable air filters in exhaust and supply air streams. MOUNTING THE HRV Four threaded inserts at corners of case designed to accept four reinforced polyester straps that are supplied with the unit. DEFROST Damper defrost system. DEHUMIDISTAT Adjustable Internal Dehumidistat

heruntergeladen wurde: 2   Dateigröße: 152 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

If they do not operate continuously, then interlocking them electrically with the TFP is acceptable. Consult a certified electrician. WHOLEHOUSE AND PORTABLECONSOLE MODELS ATTENTION The TFP can be installed in several different ways. Please read all suggested methods before attempting installation. Electrical The TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch. * LEAVE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratin

heruntergeladen wurde: 2   Dateigröße: 152 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

4. A short piece (1-2 foot) of flexible ducting should be used on both sides of the TFP (Fig. 3). This will reduce vibration and noise transfer if present. NOTE: Please refer to the HRV installation manual for proper ducting of that appliance. Type 2 Installation *“Breathing T” is designed to assist in neutralizing pressure differences which can occur between HRV and TFP when joined together. TFP Hanging straps (4) Relief opening (breathing T) 6" port collars Power cord Flexible ducting Air flow

heruntergeladen wurde: 0   Dateigröße: 389 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

Moisture removal capabilities In addition to the amount of air being exchanged, moisture removal depends largely on the moisture content of both the inside and outside air. The trends below outline these principles. • The higher the indoor relative humidity, the larger the moisture removing capabilities. • The higher the indoor temperature, the larger the moisture removing capabilities • The lower the outdoor temperature, the larger the moisture removing capabilities. Detailed Calculation of Tot

heruntergeladen wurde: 3   Dateigröße: 389 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

Condensation or Ice Build Up in Insulated Duct to the Outside • incomplete vapour barrier around insulated duct • a hole or tear in outer duct covering • tape and seal all joints • tape any holes or tears made in the outer duct covering • ensure that the vapour barrier is completely sealed Water in the bottom of the HRV • drain pans plugged • improper connection of HRVs drain lines • HRV is not level • ensure O-Ring on drain nozzle sits properly • look for kinks in line • check water drain conne

heruntergeladen wurde: 2   Dateigröße: 389 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

16 Operation of the HRV These Recirculating Models of HRV's will provide fresh clean air without sacrificing the savings of your energy conserving home. When outdoor air is required for pool room dehumidification, the aluminum cores of the HRV provide effective and efficient heat recovery exchange. Whether operating as an HRV or in recirculation mode, the energy efficient PSC blower motors provide reliable and cost effective operation. Operation: Humidity control is provided by an adjustable deh

heruntergeladen wurde: 15   Dateigröße: 389 kb   Hersteller: Lifebreath  
Kategorie: Luftreiniger
@name

Due to numerous applications in which this equipment can be installed, it is difficult to predict servicing intervals. In certain situations where there is heavy smoke, servicing the equipment every one two months may be needed; whereas ventilating a meeting room for example for carbon dioxide may only need service every six months to a year. Motor Access to the motor is through the front service doors. Note heat exchanger core can be removed to provide more room. See CORE in this section. The m