Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Sharp, modell FP-R30CX

Hersteller: Sharp
Dateigröße: 1.02 mb
Dateiname: sharp_fpr30cx_manual.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Do not wash and reuse HEPA filter and Active Carbon Filter. Not only it does not improve filter performance, it may cause electric shock or malfunction. • Clean the exterior with a soft cloth only. The unit surface may be damaged or cracked. In addition, the sensor may malfunction as a result. REMOTE CONTROL LIMITATIONS DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS: • Any location where there is inverter lighting equipment or electronic spontaneous lighting equipment The remote control may become inoperative. In this case, move away from such lighting equipment or change direction. • Location exposed to direct sunlight The unit may not receive signals from the remote control. INSTALLATION GUIDELINES • During the operation of the product, please place the unit at least 7 feet(2m) away from equipments which involve electric wave such as televisions, radios or wave clocks, in case electrical interference occurs to such equipments. •Avoid a location where the sensor is exposed to direct wind. The unit may not operate properly. •Avoid locations where curtains, etc., come into contact with the intake or air outlet. Curtains, etc., may become dirty or a malfunction may occur. •Avoid locations where the unit is exposed to condensation, due to drastic temperature changes. • Place on a stable surface with sufficient air circulation. • Do not install when there is generation of lampblack, such as in a kitchen, etc. The unit surface may crack or the sensor may malfunction as a result. • Leave at least 2 feet(60cm) of space from the wall. The wall behind the air outlet may become dirty as time passes. When using the unit for extensive period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall, etc. ENGLISH FILTER GUIDELINES • Follow the instructions in this manual for correct care and maintenance of the filters. E-7 E-8 QUICK CLEAN operation Indicator Light PART NAMES MAIN UNIT DISPLAY AUTO Operation Indicator Light Pollen Mode Indicator Light Odor Sensor Remote Control Receiver CLEAN-SIGN Light Fan Speed Indicator Lights Plasmacluster Indicator Light OFF Timer Display Indicator Lights POWER ON/OFF Button See Page E-12 MODE Selection Button See Page E-12 Odor Sensor Main Unit True HEPA Filter (white) See Page E-10,16 Active Carbon Filter (black) See Page E-10,16 Filter Support Front Panel Remote Control See Page E-14 Remote Control (1 unit) Battery (AA battery x 2 ) • Operation manual Handle Air Outlet Date Label Power Cord Power Plug BACK INCLUDED PREPARATION PREPARATION Remove the back cover Press and slide the back cover to remove. Insert batteries Insert batteries with and as shown below. Close the back cover Battery Information • The battery life is about 1 year. • The batteries for this remote control are for initial use only . Change the batteries when necessary. • Incorrect usage of the batteries may cause battery fluid leakage and/or damage. Take care of the following when handling: • When replacing the batteries, replace both batteries with new ones of the same type. (Use 2 AA manganese batteries.) • When not using the unit or remote control for an extended period, remove the batteries. • The batteries are for initial use only and may be depleted within 1 year. INSERTING BATTERIES IN THE REMOTE CONTROL 1 2 3 ENGLISH REMOTE CONTROL USE • Operate with the remote control facing the main unit receiver. • The signal range is about 23 feet (7m). • Make sure there are no objects blocking the path of the signal. •A beep sound will be heard from the main unit when a signal is received. NOTE •Avoid dropping or damaging the remote control, using in a high humidity condition, in direct sunlight or near a heat source. Receiver Transmitter E-9 PREPARATION Be sure to remove the power plug from the wall outlet. PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filters, they are installed in the main unit within plastic bags. Be sure to remove the filters from the plastic bags before using the unit. 1 Front Panel Remove the filters 1 1 Remove the Front Panel. Pull the bottom of the Front Panel. 2 2 Remove the Filter Support. Pinch the two tabs and lift to remove. Up side Tabs Tabs 3 3 Remove the Active Carbon Filter and True HEPA Filter. Active Carbon Filter True HEPA Filter Main Unit Remove the Active Carbon Active Carbon Filter True HEPA Filter 4 Filter (black) and True HEPA Filter (White) from the plastic bags. E-10 Install the filters 1 1 Place the True HEPA Filter within the main unit with the tabs facing up. Do not install the filter backwards or the unit will not operate properly. 2 2 Place the Active Carbon Filter on top of the True HEPA Filter. Active Carbon Filter Make sure that the tabs of the True HEPA Filter remain visible. Tabs Tabs True HEPA Filter ENGLISH 3 3 Insert the bottom side tabs of the Filter Support into the associated holes of the main unit. Next...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien