Anleitung AllerAir, modell A8PK7025
Hersteller: AllerAir Dateigröße: 1.06 mb Dateiname: 5c21ea4c-e298-4d74-9d8f-56ff19790ccb.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Operation and Maintenance Manual Units must be shipped back to AllerAir in their original packaging. Clients are responsible for insuring packages with carriers such as UPS. The warranty does not cover expendable parts such as filters and pre-filters. AllerAir Industries Inc. is not liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever. One year parts and labor. AllerAir top quality air purification machines are distributed worldwide for commercial, residential, institutional and industrial use. The units employ cutting-edge technology, and are built according to the highest standards required for health and safety. 8000 Series Air Purifiers A8PK7025 Model # Serial # Congratulations! You're moments away from fresher, cleaner indoor air. Your new AllerAir unit will combat many of the chemicals, gases, odors and particles responsible for poor indoor air quality (IAQ) . Poor IAQ may cause or worsen allergies, asthma, multiple chemical sensitivities ( MCS) and sick building syndrome. We recommend proper maintenance of your unit to keep it running efficiently for years to come. Operation: All units except D and DX models are shipped fully assembled and ready for use. ( D and DX model owners may refer to their additional instruction sheet for filter installation, or refer to Page 3 of this booklet. ) NOTE: As original packaging is required for warranty returns, new AllerAir owners are advised to keep boxes and shipping materials. July/23/2007 AllerAirIndustriesInc. Tollfree: 1-888-Fax: 1-877-allerair. comAllerAirIndustriesInc. Tollfree: 1-888-Fax: 1-877-allerair.com GETTINGSTARTED Keep packaging in case of warranty returns Filters are shipped in a separate box, and must be installed prior to use. Refer to Page 3. Wipe the unit with a soft damp cloth to remove dust accumulated during shipping Check the inlet opening for extra prefilters if ordered Lay the unit on its casters and plug it into a 120-volt outlet with ground Run the unit on TURBO for a few minutes to re-adjust the airflow patterns in the room Depending on interior conditions, you may choose to run the unit on HIGH during the day and on LOW at night* Running the unit on LOW is energy-efficient and increases the amount of air dwell time in the cleansing chambers * Depending on interior dust conditions. But for chemical, smoke or VOC odors we suggest operating on the low setting to allow for the longest dwell time and adsorbtion. REPLACINGORCLEANINGTHEPRE-FILTER We recommend changing or cleaning pre-filters every one to two months. STEP A STEP B Turn the unit off, unplug it, and gently lay it on its side. Slowly remove the dirty pre-filter to avoid dispersing its contents. To clean: Carefully vacuum both sides of the filter or replace with new. To discard: Gently insert into a plastic bag and discard. STEPC Gentlypressthepre-filterflatagainsttheinnerwallsoftheinnermostfilter. Returntheunittoanuprightposition. [ Warning ] Refrain from poking or sticking any object into the unit's air vents Pre-filter Order Reference Numbers* To order a new pre-filter, call AllerAir toll-free at 1-888-852-8247 during regular business hours (EST) , or send an e-mail to info@allerair.com THEALLERAIRAIRFILTRATIONSYSTEM ACTIVATED CARBON Your AllerAir air purifier contains activated carbon that permanently traps dangerous airborne chemicals, gases and odors. This vital filter should be changed approximately every two to three years, depending on the environment in which the unit is operating. You can also upgrade your Exec, Vocarb or D unit at any time to accommodate a larger and deeper carbon filter suitable for removing heavier concentrations of chemicals, gases and odors. PRE-FILTER The pre-filter included with your unit removes larger particles and helps prolong the life of your HEPA filter. The pre-filer should be vacuumed or replaced every three months. LASER TESTED, MEDICAL-GRADE HEPA* HEPA or high-efficiency particulate air filters were originally developed by the military to remove radioactive dust, and are now the primary particle filtration systems used in hospitals, laboratories, electronic clean rooms and any application where clean air is critical. Today, HEPA filters are widely recommended by allergists, doctors and indoor air quality experts for home and office. They trap an amazing 99.97% of airborne particles at 0.3 microns, including dust, hair, pollen and even some bacteria and viruses. Depending on the particle level in the environment in which the unit is used, your HEPA filter should be replaced every three to five years. * Note that chemical and odor models D and DX feature a micro-particle filter which is rated to trap at least 95% airborne particles. THE ALLERAIR ADVANTAGE · Our units offer complete air filtration removing airborne chemicals, gases, odors and particles. · Our deep bed, activated carbon filters last longer than the average thin filter which is generally carbon sprayed onto a synthe...