Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Oreck, modell AIR7

Hersteller: Oreck
Dateigröße: 872.78 kb
Dateiname: e06f9e75-5696-4279-973a-5fa83cf266fe.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2. FRAGRANCE CARTRIDGE: Fragrance compartment switch ejects drawer for access to fragrance cartridge. Insert fragrance cartridge and close drawer. One fragrance cartridge included. 3. IONIZER POWER SWITCH: Turns the ionizer ON or OFF. The indicator light will glow green when ON and functioning properly. 4. POWER INDICATOR LIGHT: The indicator light will glow green when the unit is operating normally. It will flash red when the collector cell requires cleaning. NOTE: The light will glow red for a moment when unit is first turned on. This is normal and only a test of the system. 5. AIR DIRECTION CONTROL: Slide switch on top of unit controls the louvers and enables you to direct airflow to desired areas. NOTE: You may notice an occasional infrequent sharp snapping sound coming from your unit. This is a normal occurrence called “arcing” and results as large particles of dust are collected in the ionizing-collecting cell. Should prolonged or continuous arcing occur, the ionizing-collecting cell should be thoroughly cleaned and dried completely (See “Cleaning Collector Cell”). Instructions WARNING: DO NOT USE THIS ELECTRONIC AIR PURIFIER WHEN OXYGEN TANKS ARE BEING USED OR IN THE PRESENCE OF COMBUSTIBLE GASES. 3 IMPORTANT NOTES: . Your air purifier works best if you leave it in operation all the time. . Place or mount the air purifier near a standard electrical outlet. Do not block either the air intake or outlet grill. . Never place your air purifier on soft surfaces (such as bed, sofas or carpet), near computers or next to sources of heat (such as stove tops, ovens, etc.) . Make sure the front grill is securely locked in place. . A safety switch is installed behind the grill of your electronic air purifier. If the grill is not properly secured in place, the unit will not operate. If your unit fails to operate, remove the front grill and reinstall it, being sure that the lower right-hand side of the grill (next to the control panel) is firmly locked in place. . Plug the power cord into the nearest available standard electrical outlet. (See data label on bottom of your air purifier for electrical specifications and power consumption.) . Do not use an extension cord to supply power to your air purifier. Cleaning The Cabinet You can clean the air purifier cabinet with mild, non-abrasive cleanser and a soft cloth. IMPORTANT: Unplug the unit from its electrical power source. Do not spray cleansers or furniture polish into the louver or grill areas. Collector Cell Indicator light is green under normal operation and flashes red when the cell requires cleaning. To clean, proceed as follows: The red "WASH CELL" light will flash or illuminate when it is time to clean your cell. However, it is recommended that every four to eight weeks or if snapping sounds become frequent, clean your electronic air purifier. Your electronic air purifier is still filtering the air when the red light illuminates. Cleaning your electronic air purifier is a snap too... and a must for efficient operation. 1. Turn the unit off and unplug it from the electric power source. If wall mounted, remove unit from wall. 2. Remove front grill by unscrewing the retainer screw under the grill on the cabinet bottom. (fig. 1) 3. Pull the cell out of the cabinet by using the two small handles on the front of the cell. (fig. 2) 4. Snap off the charcoal odor absorber from the back of the cell. Change as necessary for continued odor removal. (fig. 3) 5. Slide off pre-filter. This can be cleaned with the cell and reused. (fig. 4) NOTE: Handle the electronic cell with care. Damaged metal plates and/or broken wires will cause the air purifier to malfunction. (Do not wash charcoal odor absorber; it is disposable.) Cleaning with Assail-A-Cell® Cell Cleaner: 6. Using Assail-A-Cell® Cleaner, thoroughly saturate the cell and prefilter. Be sure to spray between each cell plate and cover every surface. Allow product to soak for a few minutes, not allowing it to dry. Rinse thoroughly with water. For extremely heavy deposits, repeat the process. IMPORTANT: Dry the collection cell thoroughly outside of the air purifier before reinstalling it into the air purifier. Ensure that all areas including corners and areas that may trap water are dry before reinstalling into the air purifier. DO NOT place a wet or damp collection cell in the air purifier. Replacing the Charcoal Odor Absorber (Optional) In addition to air purification, your Oreck provides the additional benefit of odor removal. The odor removal function is optional. Your Oreck Air Purifier will continue to remove harmful airborne particles with its permanent electronic collector cell even if you choose not to use the optional charcoal odor absorber. Odor absorption effectiveness will gradually deteriorate over time unless the charcoal odor absorber is replaced. While every environment is different, Oreck suggests that the charcoal odor absorber be replaced every two months or as needed. IMPORTANT: DO NOT wash the charc...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien