Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Honeywell, modell 18150

Hersteller: Honeywell
Dateigröße: 371.04 kb
Dateiname: 8dbf803d-b11c-4cd2-9a22-9f0a49f131b9.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


It should be checked monthly and replaced at least every 3 months. If there are heavy concentrations of odors, smoke, or large particles in the home, you may need to change the pre-filter more often. We DO NOT recommend operating the air cleaner without the activated carbon pre-filter or without following the filter replacement guidelines. Whenever the air resistance of the HEPA filter becomes excessive due to the amount of contaminants it has captured, the air volume output will begin to reduce and the sound level of the air cleaner will increase. Storage... If you store your Honeywell HEPA air cleaner for more than 30 days, we recommend: • Removing both the primary HEPA filter and the activated carbon pre-filter from the unit. • Discarding the pre-filter. • Wrapping the HEPA filter in an air-tight plastic bag or plastic wrap. Be sure that the filter is totally sealed. To restore the air cleaner to service, unwrap the HEPA filter, install a new activated carbon pre-filter, and reinstall both filters in the air cleaner. See “How to Install and Replace the Filters...” section for proper installation. How to Install and Replace the Filters… INSTALL PRE-FILTER BEFORE INITIAL OPERATION. The initial pre-filter is packaged separately to ensure its freshness. BEFORE initial operation, locate the pre-filter in the box, remove it from its packaging and install per instructions below. 1. DISCONNECT FROM POWER SUPPLY BEFORE SERVICING. 2. Replace filter(s) and re-assemble unit per instructions below. 3. Plug in and RESET appropriate filter monitor(s). To Replace HEPA Filter: 1. Unscrew handle counter-clockwise. 2. Remove top cover. 3. Replace HEPA Filter (there is no top or bottom to filter). 4. Replace top cover. 5. Insert and tighten handle clockwise. To Replace Pre-filter: 1. Place unit on its side. 2. Push in on both tabs on base ring to release base (per diagram). 3. Gently remove base from motor assembly. 4. Install initial pre-filter or replace used one. Wrap prefilter around Base Ring and attach with fastener provided. 5. Align base into grooves and gently snap back into place. Troubleshooting Open Close Handle Handle HEPA Filter Pre-filter installed on Base Ring Groove Push in on both tabs to release Base Ring HEPAFILTER HIGH POWER MED PREFILTER LOW Important – this air cleaner has been designed to operate very quietly and effectively without a cool exhaust draft, especially on lower speeds. • Start on HIGH for a few minutes, then adjust to desired speed. • This product may emit a “new” smell which will disappear over a relatively short period of operation. • Check to make sure that the power cord is correctly connected to the outlet. • Test that the outlet is functioning properly using another appliance or lamp. • Check the fuse or circuit breaker. The outlet may be overloaded if other appliances are also in use. Determine and correct the cause of the overload. • If none of the above procedures restore operation, return your unit to the store. If the store's return policy does not allow the return, return the complete unit per the instructions in the warranty section of this owner’s guide. Do not attempt to repair the unit yourself as it may cause injury, and the warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual. 5 Year Limited Warranty… Honeywell HEPA Air Cleaners Model No. 18150 Series This product has been engineered and crafted with great care for your satisfaction. Be sure to fill out and return the enclosed card within 10 days of purchase. A. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship within 5 years of the date of purchase. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. HONEYWELL IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS LIMITED WARRANTY. Some regions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from region to region. This warranty applies only to the original Purchaser of this product. B. At its option, Honeywell will repair or replace this product if it is found to be defective in material or workmanship within the limited warranty period. Defective product should be returned to the place of purchase in accordance with store policy or to Honeywell. C. This warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in acco...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien