Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Honeywell, modell 17005

Hersteller: Honeywell
Dateigröße: 747.14 kb
Dateiname: f62fbeff-b76e-4145-a6be-20cce7551ee3.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


® IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR CLEANER When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before operating the air cleaner. 2. Place air cleaner where it is not easily knocked over by persons in the household. 3. Always turn the air cleaner to the OFF position and unplug from the wall outlet when not in use. 4. To disconnect the air cleaner, first turn control to the OFF position, grip the plug and pull it from the wall outlet. Never pull by the cord. 5. Do not use any product with a damaged cord or plug or if product malfunctions, is dropped or damaged in any manner. Keep the cord away from heated surfaces. 6. Do not use air cleaner outdoors. 7. Never use air cleaner unless it is fully assembled. 8. Do not run power cord under carpets, and do not cover with throw rugs. Arrange cord such that it will not be tripped over. 9. Do not use air cleaner where combustible gases or vapors are present. 10.Do not expose the air cleaner to rain, or use near water, in a bathroom, laundry area or other damp location. 11. The air cleaner must be used in its upright position. 12.Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner. Do not block air outlets or intakes. 13.Locate air cleaner near the outlet and avoid using an extension cord. 14.This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature. 15. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet. 16.Do not sit, stand or place heavy objects on the air cleaner. 17.Disconnect power supply before servicing. WARNING: To Reduce The Risk of Fire or Electric Shock, Do Not Use This Air Cleaner With Any Solid-State Speed Control Device. CAUTION: The battery used in this device may present a risk of fire or chemical burn if mistreated. Do not recharge, disassemble, heat above 100° C (212°F), or incinerate. Replace battery with Panasonic CR 2032, 3V only. Use of another battery may present a risk of fire or explosion. Congratulations You now own a quality portable HEPA air cleaner that has been engineered and crafted for your satisfaction. Our Consumer Relations representatives will be pleased to help with any questions or concerns you may have about your air cleaner. Please call our Consumer Relations Dept. at (800) 332-1110 for assistance, or e-mail us at service@honeywell.com. For Best Performance Indoor air can be quickly contaminated by activity in a room, infiltration of outside air, and from sources of contamination. Therefore, it is generally recommended that you operate your air cleaner 24 hours a day. However, this unit is equipped with convenient, energy-saving programmable controls which will allow you to preset the air cleaner to shut off when you are away and turn on when you generally use the room, thus minimizing energy costs. For best performance, set the air cleaner to turn on about an hour or so before you will use a room. This air cleaner discharges filtered air upwards into the room, allowing the unit to be placed on the floor in almost any location. While all the air in a room will not be processed by the air cleaner, the more air circulated through the filter, the more filtered air returned to the room. Portable air cleaners will be much more effective in rooms where all doors and windows are closed. NOTE: Due to the large volume of air drawn towards the air cleaner, surrounding areas should be cleaned and/or vacuumed more frequently to prevent dust build-up. If the unit is placed on light colored carpeting, a small mat or rug should be used to ease cleaning and prevent permanent staining of carpeting. This is particularly important in homes with heavy contamination from smoking or fireplaces. Construction speed filter setprogram minutes hours M20124 Endcap Locking Mechanism Motor Pre-filter Remote Control HEPA Filter Housing Programmable Control Features Your programmable control features include (Fig. 1): • Manual control or automatic programmed operation • 3 Speed settings • Customize set program times • Clock • Intelli-CheckTM Pre-filter life monitor bar • Intelli-CheckTM HEPA filter life monitor bar • Filter reset function • Low battery indicator Set-Up • CONNECT THE BATTERY. The programmable controls and real time clock are battery backed. Upon initial set-up, pull the protective film from the battery door so the battery will make contact and funct...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien