Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Guardian Technologies, modell Hygia 4.0

Hersteller: Guardian Technologies
Dateigröße: 214.79 kb
Dateiname: 2a2ddabc-28d3-4e41-8e10-c42399ca6934.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


11/17/06 2:04 PM Page 1 germguardiarr 1-866-603-5900 Guardian Technologies LLC 26201 Richmond Road, Unit A3 • Bedford Heights, OH 44146 1-866-603-5900 • ©2006 Guardian Technologies LLC S-7 table top Germ Guardian™ hygia'4.0 Hygia 4.0 Table Top Air Purifier USE & CARE INSTRUCTIONS English Manual..........................................................E-1 French Manual..........................................................F-1 Spanish Manual........................................................S-1 MODEL NO. AC-4000 1 Year Limited Warranty Date Purchased month 1-866-603-5900 year Hygia 4.0 3L rev.: Hygia 4.0 3L rev. 11/17/06 2:04 PM Page 2 INTRODUCTION Thank you for purchasing the Hygia 4.0 Table Top Air Purifier. Please read and save these instructions. SAFETY PRECAUTIONS Please read the following precautions carefully before operating the Hygia 4.0 Table Top Air Purifier. Failure to do so could result in a fire hazard, electrical shock, bodily injury or damage to the unit. • Do not damage, pull, twist, bend or place heavy objects on the electrical cord. • Never handle the electrical cord with wet hands. • Do not alter the plug in any way. • Do not use with extension cords. • Never tug on the electrical cord to unplug the unit from the outlet. • Unplug the unit before cleaning, installing or replacing filters. • If the electrical cord becomes damaged, please contact a qualified technician for repair. • Do not place fingers or foreign objects into the airflow openings of the unit. • Operate the unit in a well-ventilated area. • Do not operate unit with any other power supply other than the one provided. • Do not operate the unit outdoors. • Do not operate near flammable gases. • Do not operate the unit in humid or wet places such as a bathroom. • Do not use chemical sprays near the unit, they will accumulate on the filter and potentially cause harmful fumes. • Do not operate the unit in an area with high oil content, such as mechanical oil or cooking oil, over time it will deteriorate the filter. • Never look directly at the UV-light bulb when lit. • Make sure all filters are correctly installed before running the unit. • This is not a toy and is not intended for use by children. For adult use only. • Do not defeat interlock switch. E-2 IDENTIFICATION OF PARTS Main Unit 1. Control Panel 2. Vent Adjustment Lever 3. Filter Door 4. Filter Release Button 5. HEPA and PCO Filter 6. Ionizer Control Panel A. On/Off B. High Fan Speed C. Low Fan Speed D. Ionizer On/Off Hygia 4.0 3L rev.: Hygia 4.0 3L rev. 11/17/06 2:04 PM Page 3 INSTALLATION The filter can be found packaged inside the Air Purifier. It is recommended to replace the filter every six months to maintain optimal performance. Installing the Filter 1. Unplug the Hygia 4.0 from the electrical outlet. 2. Unplug the electrical cord from the Hygia 4.0. 3. Turn unit over so the filter door faces you. 4. Using a coin, turn the round filter release button to the left so the line in the center is facing vertically. 6. Gently pull filter from unit and remove bag. 8. To install new filter reverse steps 1 - 7. Replace filter into compartment. E-4 INSTALLATION (cont.) Features Levels of filtration include: 1. Charcoal filter removes odors and smoke. 2. HEPA filter captures 99.9% of airborne particles. 3. PCO filter captures and dissolves airborne allergens and mold. 4. Ionizer - Emits small amount of ions to freshen the air. Cleaning the Unit WARNING: To avoid serious injury from electric shock, the unit must be turned OFF and unplugged from the power outlet prior to any cleaning. 1. TURN THE UNIT OFF AND UNPLUG THE UNIT FROM THE POWER OUTLET. 2. Clean unit with a damp soft cloth only. DO NOT pour or splash water on the unit or use any abrasive type cleaner. Clean all external surfaces, especially the air intake grills and air outlet. 3. Reposition the unit, plug power cord into power outlet and turn ON. Hygia 4.0 3L rev.: Hygia 4.0 3L rev. 11/17/06 2:04 PM Page 4 TECHNICAL SPECIFICATIONS Length Width Height Weight 8 in. 7 in. 3 in. 1.25 lb Input Voltage 120 volts AC, 60Hz REPLACEMENT PARTS Part Number Part Name Size Weight FLT-4000 Hygia 4.0 Air Purifier Replacement Filter iir Purifier Replacement Filter 5.25L X 5.25W X ,5H 2.4oz LIMITED WARRANTY To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. Refer to your product carton for the length of warranty and save your original sales receipt to validate start of warranty period. If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. The complete machine must be delivered pre-paid to any authorized Guardian Technologies LLC warranty service center. Please include complet...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien