|
Anleitung Zusammenfassung
See sketch A. CAUTION: IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE ADEQUATE MOUNTING COMPONENTS ARE USED. DO NOT ALLOW WEIGHT OF UNIT TO REST ON SUSPENDED CEILING SUPPORT RAILS. g) Make electrical connections as detailed in next section. h) Re-install cell and prefilter. i) Close access door and unit is ready for operation. SOLID CEILNG MOUNTING To mount the unit to a solid ceiling, proceed as follows: a) Unpack the unit, open filter access door and remove prefilter and cell (see filter removal in section 2). b) Select a location near the center of the area to be cleaned. lf you are fitting to wooden ceiling joists, locate the position of joists. c) Using the template provided, drill four holes into the ceiling and fit four 5/16 lag screws in the joists. Hex-headed screws will give easier access for final tightening. Do not tighten fully home. d) Lift the unit to where the large end of the keyhole slots in the top of the cabinet fit over the screw heads. Slide the unit so that the narrow ends of the mounting slots are located under the screw heads. Tighten the screws fully home. e) Install the lockdown location screw as shown on template. f) Make electrical connections as detailed in next section. g) Re-install cell and pre-filter. h) Close access door and unit is ready for operation. WALL MOUNTED (SE400E Only) Filter removal will be simpler if the unit is positioned with the access door hinge in a vertical plane. Locate the wall studs and follow the mounting instructions for SOLID CEILING MOUNTING. ELECTRICAL:WARNING: THIS APPLIANCE MUST BE ELECTRICALLY GROUNDED. NOTE: This unit is designed to bepermanently connected to fixedwiring. Installation must comply with all applicable electrical codes. 5 Hard wired remote control Two sets of wiring are required to connect the unit. Main power to the unit is 120V, 60Hz, 1Ph, rated 5 Amp -Live, Neutral and Ground. A 5-conductor 5 Amp rated cable is required from the unit to remote control. Run the 5-conductor cable and the main power connection through the cable entry knockouts (see Fig. 5) in the cabinet and connect to the input terminal block (Fig. 6) as shown in the wiring diagram on page 10 and 11. Mount the remote control in the desired position and connect the 5-conductor cable leads to the numbered terminals as shown in the wiring diagram. OPTIONAL INFRARED CONTROL Main power to the unit is 120V, 60Hz, 1Ph, rated 5 Amp - Live, Neutral and Ground. To install, follow the instructions included with the infrared control kit. 6 2. Diagrams FIGURE 1. FIGURE 2. FIGURE 3. FIGURE 4. FIGURE 5. FIGURE 6. 7 Section III – Service and Maintenance 1. SERVICING AND MAINTENANCE Beyond an occasional wipe down with a damp cloth, the units need little in the way of maintenance. However, the units are designed to collect airborne dirt and from time to time will require routine servicing to remove the accumulation. The service interval varies considerably between applications, but typically will range from six weeks in a busy bar up to several months in a quiet office. During normal operation, the unit will make an occasional snapping noise. This is caused by large pieces of dirt accumulating on the electronic filter and is not dangerous. The Trion SE400E & SE800E units have anti-arcing circuitry to eliminate the nuisance of constant arcing. If, however, the arcing occurs every minute or two, it is an indication that the unit needs cleaning. When a service is due proceed as follows: a) Remove pre-filter and either vacuum clean it or wash as described below. b) To clean the electronic filter, soak it in a hot (not boiling), a strong non-caustic detergent solution cleaner. Trion can supply an excellent detergent-TriDexobtainable through your Dealer. Alternatively, a dishwasher detergent does an excellent job. Soak the collector cell for several hours, then rinse with clean water. Do not physically try to rub the dirt off since this can cause damage to the filter. c) Allow the filter to dry thoroughly -preferably overnight- and replace into the unit or alternatively use force air dry setting on the unit. Trion has a policy of continuous productimprovement, and reserves the right to makechanges in design and specification withoutnotice. 2. PARTS LIST Item Part Number Description Qty/UnitSE400E Qty/UnitSE800E 1 454027-001 Cabinet Assembly, SE400E 1 - 2 454028-001 Cabinet Assembly, SE800E -1 3 453844-001 Cell Access Cover 1 - 4 453844-003 Discharge Cover 1 2 453845-001 Cell Access Cover -2 6 153853-001 Hinge Pin 2 4 7 453855-001 Grill 4 6 8 453856-001 Corner 4 4 9 453857-001 Grill Filler -2 253863-001 Pre-filter 1 2 11 441730-103 Collector Cell 1 2 12 150685-001 Cell Retaining Clip 1 2 13 353842-001 Cell Latch 1 2 14 153854-001 Thumb Screw 1 2 244225-002 Bolt Retainer 1 6 16 345109-001 Cell Contact Assembly 1 2 17 453840-001 Cell Contact Support 1 - 18 453841-001 Cell Contact Support -1 19 242404-002 Interlock Switch 2 4 147214-001 Insulator 2 4 21 350950-003 Power Supply Assemb...
Dieses Handbuch ist für folgende Modelle:Luftreiniger - ELIMINATOR SE800E (1.17 mb)