Filter(s) OK Replace Filter(s) 1 2 The carbon pre-filter will last approximately three months. NOTE: You must reinstall and snap the intake grille before checking the filters with the gauge. The air purifier will not operate if the grille is not in place. Insert either end of the filter check gauge into the recessed hole on the top of outlet grille. Turn the fan on QuickClean.™ The colored cylinder should float up the filter check gauge. If it does not move from the bottom of the gauge, the filter(s) are clogged and need to be replaced. 10 840129900 ENv02.qxd 11/1/04 11:02 AM Page 11 Replacing the HEPA Filter The HEPA filter will normally last about 12 months before it must be replaced, or approximately every fourth time the carbon pre-filter is replaced. 1 2 If the filter check gauge indicates that the filter requires replacement, it is recommended that you first replace the carbon pre-filter and then use the filter check gauge to check the filter again. If the colored cylinder still does not float up the gauge, the HEPA filter must also be replaced. Turn off and unplug air purifier. Remove the used HEPA filter by gripping the sides and pulling outward, as shown. Discard the used filter. It cannot be cleaned. Obtain a replacement HEPA filter. Insert the unwrapped HEPA filter, hook fastener side out, into the air purifier. NOTE: Improper filter installation will result in poor air filtration. 11 840129900 ENv02.qxd 11/1/04 11:03 AM Page 12 Replacing the UV Bulb The UV bulb is designed to provide approximately one year of continuous, effective operation. After this time, the bulb may remain illuminated, but its effectiveness is greatly reduced. 1 2 For maximum germicidal protection, replace the UV bulb when replacing the HEPA filter, or if the UV bulb check window does not glow when the UV switch is on. Replacement bulbs can be obtained directly from Hamilton Beach. Turn off and unplug the air purifier. Open and remove the outlet grille by pulling upon the handle on the upper back of the air purifier. Gently rotate the bulb a quarter turn in either direction until it unlocks from the socket. Pull the pins out the sides of the socket, one end at a time. Be careful not to touch the glass part of bulb. Handle by metal ends only. Oil from fingertips on the glass bulb will shorten the life of the bulb. Carefully unpack the bulb and discard the packaging. Starting with one end of the bulb, then the other, gently insert the metal pins on the bulb into the white slotted socket one pin at a time. NOTE: Only one pin will fit in the socket at a time. DO NOT force the pins into the socket—you could break the bulb. 12 3 840129900 ENv02.qxd 11/1/04 11:03 AM Page 13 Replacing the UV Bulb (continued) 4 5 6 Once the ends of the bulb are completely inserted into the socket, rotate the bulb a quarter turn until it locks into place. Insert the two center tabs on the front of the outlet grille into the middle slots on the front of the opening. Pivot the grille down toward the back of the air purifier. Press lightly down on the back corners of the outlet grille to snap it into place. NOTE: The air purifier has a safety switch that prevents operation when the top outlet grille is not properly installed. DO NOT attempt to override or disable this safety switch. See the Germicidal Light Hazard Warning on page 3. 13 840129900 ENv02.qxd 11/1/04 11:03 AM Page 14 Replacing the UV Starter 1 Starter If the UV bulb does not light after installing a new bulb, the starter should be replaced. See page 3 for replacement parts. Turn off and unplug air purifier. Remove the intake grille and filters. The starter is the small cylinder-shaped part located behind the filter. 2 Turn the starter counterclockwise until it unlocks, then pull it out. To install the new starter, insert the starter and turn clockwise. Replace filters and intake grille. 14 840129900 ENv02.qxd 11/1/04 11:03 AM Page 15 Troubleshooting Guide The following section provides the solutions to many common problems and questions. If your air purifier is not working correctly, review these solutions first. If your problem is still not solved after reviewing this guide, call our toll-free customer service number, listed on the front cover of this manual, for assistance. The Air Purifier Will Not Turn On • Are the intake grille and the outlet • Is the fan speed knob turned on? grille installed and locked into place? • Is the air purifier plugged into a powered outlet? The Air Purifier Changes Speed • AirSmart™ models are designed to sense the level of contaminants in the air and adjust the fan speed to provide the most effective air purification possible. If the AirSmart™ control is set to Auto, it will automatically change fan speeds to adjust for changing air quality. Reduced Air Flow or Poor Filtering • The intake or outlet grille may be • The carbon pre-filter or the HEPA blocked. Make sure nothing is in filter may be clogged. Check the front of or on top of the air purifier. filte...

Dieses Handbuch ist für folgende Modelle:
Luftreiniger - 04162 (1.44 mb)
Luftreiniger - 04161 (1.44 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien