5 speed fan operation. High speed - 120 VAC, 182 Watts. FILTERS - Washable air filters in exhaust and supply air streams. MOUNTING THE ERV - Four threaded inserts at corners of case designed to accept four PVC reinforced polyester straps that are supplied with the unit. DEFROST - Damper defrost system. CASE - Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. DRAIN CONNECTIONS - Two - 1/2” (12mm) O.D. CONTROLS - ControlAir 15 WEIGHT 63 lbs. (28.7 kg) SHIPPING WEIGHT 65 lbs. (29.6 kg) PERFORMANCE Net supply airflow in cfm (L/s) against external static pressure E.S.P cfm L/s @ 0.1” (25 Pa) 214 (101) @ 0.2” (50 Pa) 206 (97) @ 0.3” (75 Pa) 193 (91) @ 0.4” (100 Pa) 184 (87) @ 0.5” (125 Pa) 170 (80) Sensible Effectiveness @127cfm (60 L/s) (CSA C439M) 67% Sensible Efficiency 32°F (0°C) 60% Total Efficiency 55% VAC @ 60HZ 120 WATTS / Low speed 70 STALE AIR TO OUTSIDE STALE AIR FROM HOUSE FRESH AIR TO INSIDE 14 3/4" (375) 19"(483) DIMENSIONS 200ERVD inches (mm) *All Duct Connections 6"(150mm) FILTERS *NOTE: Front clearance of 25 inches (635 mm) is recommended for servicing unit. MOTOR 31" (787) FRESH AIR FROM OUTSIDE DAMPER DEFROST PORT CONDENSATE DRAINS ENTHALPIC CORE BALANCING DAMPER OPTIONS WARRANTY 99-104 Digital Electronic Timer - 20/40/60 min. (3 wire) Units carry a 5 year warranty on the energy recovery core and 99-105 Deluxe Programmable Control includes replacement parts. Programmable Time Clock, Dehumidistat and Air Sentry™ All units conform to CSA and UL standards. 99-109 Air Sentry™ Air Quality Monitor designed to accept ERVs are not recommended for regions where the remotely mounted Control Pad. design temperature is below 25°F (-4°C) 99-186 Weatherhoods, Two - 6” (150mm) c/w 1/4” (6mm) mesh screen DATE: __________________________ 511 McCormick Blvd. London, Ontario N5W 4C8 PROJECT: __________________________________________ Ph: (519) 457-1904 Fx: (519) 457-1676 Email: nutech@lifebreath.com Website: MECHANICAL CONTRACTOR: _____________________________ 12 TI-200ERVD Operating the ControlAir 15 Plugging in the HRV/ERV energizes the unit. A self test function will be performed every time the HRV/ERV is energized (refer to “Self Test” for more details). After the self test has completed successfully the HRV/ERV will default to Speed 1. This is the factory default setting. Follow the instructions found on the HRV/ERV door to select desired mode and speed, or refer to the instructions found on the following page. Removing and relocating the Control Pad The Control Pad can be removed and installed in a remote location (100’ wire length max). The Control Pad can be installed in a 2x4 box with a “Decora” type cover plate or can be installed in the optional “Ventilation Dehumidistat” or “Air Sentry”. When the Control Pad is installed in a remote location, all optional controls will still be wired to the Control Module on the HRV/ERV. When remotely mounted on its own, the Control Pad is wired to the Control Module by 3 wire (min. 20 gauge). Connect the colour coded terminals to the corresponding terminals on the Control Module. When the Control Pad is remotely mounted in the Ventilation Dehumidistat or Air Sentry, refer to optional controls page for wiring requirements. Self Test Each time the HRV/ERV is powered/energized the self test function will automatically initiate. During the self test the HRV/ERV will cycle through all the speeds available (1-5), test the damper motor operation and will default back to the previous mode/speed selection, (factory default is Speed 1). Total self test duration is approximately 1 min. 30 sec. Automatic Defrost Operation (Not on all models) The advanced technology of the digital microprocessor automatically activates the defrost system only as it is needed. To be an efficient heat recovery device, the HRV/ERV must effectively provide for core defrost as well as providing efficient heat exchange. As outdoor conditions cool, the temperature sensor (thermistor) tracks the supply air temperature. The thermistor then sends its signal to the microprocessor (circuit board) which initiates only the defrost cycle time required to clear the core. On recirculating defrost models, the core is defrosted when the supply air port is automatically blocked off and exhaust air is redirected back through the HRV/ERV. On damper defrost models, the core is defrosted when the supply air port is automatically blocked off and the warm air surrounding the HRV/ERV is drawn in through the defrost port. The mode indicator will flash RED during the defrost cycle. This dramatic advance makes more energy available for recovery as the unit spends less time in defrost mode. By optimizing the defrost cycle, the HRV/ERV combines money saving performance with a well designed and reliable control system. FUNCTION & CONTROL Glossary DEFROST MODE - to ensure reliable operation during cold weather, the HRV/ERV will automati...
Dieses Handbuch ist für folgende Modelle:Luftreiniger - Air Purifier 155MAX (1.05 mb)
Luftreiniger - Air Purifier 200MAX (1.05 mb)
Luftreiniger - Air Purifier 300DCS (1.05 mb)
Luftreiniger - Air Purifier 95MAX (1.05 mb)