Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Ionic Pro, modell TP 300D

Hersteller: Ionic Pro
Dateigröße: 1.39 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


9. Insert the top of the inlet grill first and then snap in the lower part of the grill. Rep laci ng the UV lamp UV LA MP SAFETY WARNING: To prevent exposure to ultraviolet light, disconnect power to the unit before servicing any part of the Therapure® 300D air purifier. Before replacing the UV lamp of your Therapure® 300D air purifier, turn off and unplug the unit from the electrical outlet and read all safety instructions and important warnings in this owner’s manual. Replace your UV lamp every year. Call 800.875.8577 or visit 1. First turn off and unplug your Therapure® 300D air purifier. With the front of the unit facing up, pull up the lower end of the inlet grill and push it toward the display panel at the top of the unit as shown below. 2. Remove the permanent filter by lifting and pulling the string. 3. Remove the screws on the UV shield by using a screwdriver. Allow the UV lamp to cool at least 15 minutes. 4. Remove UV sheild. 5. Gently rotate the lamp a quarter turn in either direction until it unlocks from the socket. The lamp removes and installs in the same way as a flourescent light lamp. Pull out the lamp. 6. Unpack the new UV lamp gently by handling the ends only. Starting at one end of the lamp, then the other, gently insert the metal pins on the lamp into the white slotted socket, one pin at a time. Once the ends of the lamp are completely inserted into the socket, rotate the lamp a quarter turn until it locks into place. cleaning & maintenance Caution: Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness of the lamp. Never operate the unit without a filter or with a damaged filter. The UV light from the UV lamp will result in severe damage to eyes and could cause blindness. UV Lamp Notice Warning UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision. Never look directly at the UV lamp while it is illuminated-doing so could cause loss of vision! To Order a Rep laceme nt UV Lamp If your UV Lamp(s) is broken or needs replacing, simply contact us at 1.800.875.8577 or visit us online at Therapure® replacement lamp part number is TPG63000. 300 300 troubleshooting Before contacting our customer service department, please try the following solutions: PRoBlEM REaSon SoluTIon unit won’t operate. 1. ON/OFF button hasn’t 1. Press ON/OFF button. been pressed. 2. Unit is unplugged. 2. Plug in unit. 3. The inlet grill has not been 3. Check to ensure installed or put back in place filters are properly properly. installed & the inlet grill is installed & locked into place. (See instructions on pg. 9). Reduced air flow or 1. The inlet or outlet grill may 1. Ensure nothing is in poor filtering. be blocked. front of or on top of the purifier. 2. The permanent HEPA-type filter 2. Check filter and may be clogged. clean it if necessary (See instructions on pg. 9). to order more therapure® products Our Therapure® line of products addresses a growing concern we all have regarding airborne germs. Therapure® air purifiers effectively kill bacteria and viruses with the same kind of scientifically-proven UV technology hospitals use. Therapure® air purifiers delivers pure, clean air. To find out more about our full line of air purifiers, visit us today at 14 300 15 arbitration agreement THIS ARBITRATION AGREEMENT AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY PROVIDING THAT DISPUTES BETWEEN YOU AND THE SELLER OF THIS PRODUCT MUST BE RESOLVED THROUGH BINDING ARBITRATION, RATHER THAN IN A COURT. PLEASE READ THIS AGREEMENT CAREFULLY. YOU WILL ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING THE PRODUCT(S) SHIPPED IN CONNECTION WITH THIS AGREEMENT (THE “PRODUCT”) FOR MORE THAN FOURTEEN (14) DAYS AFTER RECEIPT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, YOU MAY RETURN THE PRODUCT WITHIN FOURTEEN (14) DAYS OF RECEIPT AT NO COST TO YOU. 1. RESoluTIon oF ClaIMS oR DISPuTES. Any claim or dispute between you and the seller of this product subsidiaries or affiliates) (“collectivelly, the seller of this product”) arising out of or relating in any way to the Product or this Agreement shall be resolved through final, binding arbitration. This arbitration obligation applies regardless of whether the claim or dispute involves a tort, fraud, misrepresentation, product liability, negligence, violation of a statute, or any other legal theory. Both you and the seller of this product specifically acknowledge and agree that you waive your right to bring a lawsuit based on such claims or disputes and to have such lawsuit resolved by a judge or jury. 2. lIMITaTIon oF lEGal REMEDIES. All arbitrations under this Agreement shall be conducted on an individual (and not a class-wide) basis, and an arbitrator shall have no authority to award class-wide relief. You acknowledge and agree that this Agreement specifically prohibits you from commencing arbitration proceedings as a representative of others o...

Dieses Handbuch ist für folgende Modelle:
Luftreiniger - 1040808 (1.39 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien