|
Anleitung Zusammenfassung
Check the water supply to the that it may need to be cleaned. Contact an machine. The water may have been shut off or the authorized Scotsman service agent and have the water filter cartridges need to be changed. machine cleaned, de-scaled and sanitized. November 2006 Page 17 C1448, C1848, C2148W Air and Water Cooled User Manual Switches The two switches – on and off -can be accessed from the front of the machine. Power Status Water OffDe-Scale On • To switch the machine OFF, push and release the Off button. The machine will shut off at the end of the next cycle. • To switch the machine ON, push and release the On button. The machine will go through a start up process and then resume ice making. Control Options There are two optional, field installed controls that can be on this machine. • Vari-Smart (KVS) Adjustable ice level control • Smart-Board (KSB) Advanced Feature control Adjustable ice level control When this option is present there is an adjustment post and an additional indicator light to the right of the four indicator lights mentioned above. The ultrasonic ice level control allows the use to control the point that the ice machine will stop making ice before the bin or dispenser is full. Reasons for this include: • Seasonal changes in ice used • Planning to sanitize the bin • Faster turnover for fresher ice • Certain dispenser applications where maximum ice level is not desired Use of control 02-4294-01 Rev. A. Adjust Ice Level Lower Bin Full Vari-Smart Control Area There are several positions the ice level can be set to, including Off (knob and label indicators lined up), where it fills the bin until the standard bin control shuts the machine off. See the kit’s instructions for complete details. Rotate the adjustment post to the desired ice level. The machine will fill up to that level and when it shuts off the indicator light next to the adjustment post will be On. Note: Ice will build up in the bin or dispenser at an angle, the distances listed above will be from the sensor to the top of the ice directly beneath it. The actual distance between the highest point of the ice may be closer or further away, depending upon the angle of the ice. June 2007 Page 18 SmartBoard Ice C1448, C1848, C2148W Air and Water Cooled User Manual Options and Other Information When this option is present there is an additional display panel in the area below the main control board. It is not visible when the front panel is on. The SmartBoard’s features include: • Seven day programmable ice level setting when used with the optional Vari-Smart ice level control • Recording of machine operation, including cycle time. • Calculation of average cycle time • Recall of malfunctions with the time they occurred. SmartBoardAdvanced Feature Control ™ See Instructions for Available Features 34SEL 02-4293-01 RevA. ENTER ESC The cuber drops ice in large sections. That ice will break up into random parts as it falls into the bin, but some large sections may remain on top of the ice in the bin. When removing ice, tap the groups of ice with an ice scoop to separate them into smaller units. In a dispenser, this ice will break up into mostly individual cubes as the dispense mechanism moves the ice. Heat Air cooled models will generate heat when in operation. That heat is discharged out the back of the cabinet. Noise The ice machine will make noise when it is in ice making mode. The compressor, fan motors if air cooled and water pump all produce some sound. It is also normal to hear some cracking just before the harvest cycle begins. In addition, during the harvest cycle the harvest assist solenoid will click twice as it pushes the ice out and returns to its normal position. The ice harvests as a unit or slab, which makes some noise when it impacts the bin or dispenser. These noises are all normal for this machine. November 2006 Page 19 C1448, C1848, C2148W Air and Water Cooled User Manual Cleaning, Sanitation and Maintenance This ice system requires three types of maintenance: • Remove the build up of mineral scale from the ice machine’s water system and sensors. • Sanitize the ice machine’s water system and the ice storage bin or dispenser. • Clean or replace the air filter and clean the air cooled condenser (air cooled models only). It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without human intervention, sanitation will not be maintained. Ice machines also require occasional cleaning of their water systems with a specifically designed chemical. This chemical dissolves mineral build up that forms during the ice making process. Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine is cleaned and sanitized. The ice machine’s water system should be cleaned and sanitized a minimum of twice per year. 1 Remove the front panel. 2 Remove the evaporator cover. 3 If the machine is operating, push and release the Harvest button. When the mac...
Dieses Handbuch ist für folgende Modelle:Luftreiniger - Air and Water Cooled C1448 (2.58 mb)
Luftreiniger - Air and Water Cooled C1848 (2.58 mb)