|
Anleitung Zusammenfassung
Permanent override will remain in effect until you return the unit to auto mode. Fig. 16 Fig. 17 AUTO AUTO AUTO Temporary Override • To temporarily override the settings: 1. While the Auto Mode is active, use the UP/DOWN keys to adjust the blower speed. To temporarily turn the blower off, turn the blower speed to 0. This will allow the program to automatically continue at the next scheduled program change. 2. The air purifier will automatically adjust to the new setting. The current program number will flash to signify the temporary override. • To end the temporary override: 1. The temporary override will automatically end at the next scheduled program change. 2. To immediately end the temporary override and return to the program, press the AUTO key twice. The air purifier will return to Auto Mode and the scheduled program. Permanent Override • To begin permanent override: 1. Press the AUTO key to enter manual mode. On the display, you will see the word MANUAL illuminated. This indicates that the programs are no longer active and the unit is in Manual Mode. 2. Use UP/DOWN keys to adjust the blower speed. • To end the permanent override: 1. Press the AUTO key. The display will now show the word AUTO. 2. The unit will automatically adjust its controls to the appropriate program for the day and time. 41451-01_Rev 8-6-04.pmd 10 8/5/04, 5:05 PM Operation Filter Run-Time Counters The pre-filter and filter are critical to the proper operation of the air purifier. To help you know when to change the filters, your Hunter Air Purifier has Filter Run-Time Counters that will monitor the number of hours your filters have been in use. Although the exact life of the filters depends on the environment, the table below gives typical usage times of the filters. Table 2: Typical Usage Times of the Filters Filter Type Typical Usage Activated Carbon Pre-Filter 2000 hours HEPA Filter 8000 hours To check the run-hours for each filter: 1. Press the DISPLAY key to toggle among the 3 display modes – Clock, Pre-Filter, and Filter. The Filter or Pre-Filter indicator will illuminate when the run hours for that filter are displayed. 2. The display shows the number of run hours since the counter was reset. Although the maximum display value is 9,999 hours, the counters can go indefinitely. To indicate that the counter is over 9,999 hours, the display will flash. For example, a run time of 12,000 hours is represented by a flashing 2,000 hours. The values of the Pre-Filter and Filter Counters are stored in the air purifier’s memory. The unit may be unplugged and moved without losing the pre-filter and filter counter values. To properly track filter usage, the Pre-Filter and Filter Counters should be reset each time the filters are changed. Refer to Changing the Pre-Filter (pg. 18) or Changing the Filter (pg. 19) for instructions on how to reset the counters. Electrical Cord Storage (Selected Models Only) For your convenience, some models have cord wrap posts for easy storage of the electrical cord. The cord wrap posts are located on the back of the air purifier in the bottom corners. When received, the cord wrap posts will be in the collapsed position. To extend the cord wrap posts, simply twist approximately 1/8 of a rotation and gently pull outward. The post will extend approximately 0.5 inches (see Fig. 18). Once extended, simply wrap the cord around the two posts until the desired length is obtained. Fig. 18 - Extended Cord Wrap Posts 11 41451-01 41451-01_Rev 8-6-04.pmd 11 8/5/04, 5:05 PM 41451-01 12 Programming Setting Day and Time Setting the correct day and time allows the programs to work effectively and provides a clock for your reference. Although the instructions for setting the day and time are listed under Initial Operation, they are repeated below for your convenience. Fig. 19 Fig. 20 Fig. 21 Fig. 22 DAY/TIME DAY/TIME DAY / TIME DAY / TIME Adjusting Day and Time: (For example, Wednesday at 3:45 pm) 1. To set the day or time, press the DAY/TIME key. All display features except the day and time will go blank and the hour will flash. 2. Use the UP/DOWN keys to adjust the hour. Tapping the key will advance the hour by increments of one. Holding down the key will change the hour rapidly. Note the AM/PM indicator as you cycle through a 24 hour period. 3. Press the DAY/TIME key again. Now, the minutes will be flashing. Use the UP/DOWN keys to adjust the minute. Tapping the key will change the minute by increments of one and holding the key will change the minute rapidly. 4. Press the DAY/TIME key to accept the minute setting and go to the day of the week. Use the UP/DOWN keys to set the current day. 5. Press the DAY/TIME key a final time to accept the day setting and return to Normal mode. 41451-01_Rev 8-6-04.pmd 12 8/5/04, 5:05 PM Programming NOTES: • The clock flashes when the time has not been set. • At any time while you are setting the Day/Time, you can press the PROGRAM key to toggle between AM/PM format and military time form...
Dieses Handbuch ist für folgende Modelle:Luftreiniger - 30130 (1.06 mb)
Luftreiniger - 30400 (1.06 mb)
Luftreiniger - 30401 (1.06 mb)
Luftreiniger - 30170 (1.06 mb)