Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung White Rodgers, modell ACB1400

Hersteller: White Rodgers
Dateigröße: 341.57 kb
Dateiname:

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


This will prevent any electrical shocks. 2. Follow a regular service and maintenance schedule for efficient operation. TABLE OF CONTENTS Rules for Safe Installation and Operation ............2 How the Air Filter Works ......................................3 Construction of the Air Filter Compartment .........3 Preinstallation.......................................................4 Installation ............................................................6 Maintenance.........................................................7 Repair and Upgrade Parts ...................................7 DID YOU GET THE RIGHT SIZE AIR FILTER COMPARTMENT Model ACB & ACM1000 are designed for heating or cooling blowers delivering 600 to 1200 cubic feet of air per minute (cfm.) Model ACB & ACM1400 are designed for heating or cooling blowers delivering 1000 to 1600 cfm. Model ACB & ACM1600 are designed for heating or cooling blowers delivering 1200 to 1800 cfm. Model ACB & ACM2000 are designed for heating or cooling blowers delivering 1600 to 2200 cfm. Before installing the filter, make sure you have selected the proper size unit for your heating and cooling system requirements. See specifications on page 4. BASIC TOOLS REQUIRED Tin Snip Screwdriver Rule or Tape Measure Drill 2 5" FILTER 5" FILTER Dirty air flows through your return air ducts and enters the compartment where particles (hair, lint, etc.) are removed by the filter. See figure 1. Filtered air re-enters to the supply duct system of your building. DIRTY AIR IN FILTERED AIR OUT Figure 1 CONSTRUCTION OF THE AIR FILTER COMPARTMENT Not only is your air filter compartment easy to install, it is also easy to maintain. Its basic components, and their AIR FILTER COMPARTMENT functions, are as follows: (See Figure 2) Air Filter Compartment- mounts to existing duct work and houses the filters or optional electronic air cleaner DOOR cells. NOTE: To upgrade your air filter compartment with a high efficiency Electronic Air Cleaner, use the ACR (Air Cleaner Retrofit) Kit for your model. See page 7 for details. 5” Filter - collects dust, dirt and other particles. 5" FILTER Figure 2 3 PREINSTALLATION LOCATING THE AIR FILTER Your air filter must be mounted in the return air duct of a central forced-air system, on the air entering side of your furnace. (See Figure 3 for example.) Select a location that meets the following: 1. The face of the filter will be at a right angle to the air stream. 2. Allow 25” of clearance in front of the air filter compartment door to permit removal of filters. See figure 4 for complete compartment dimensions. 3. The air filter is not to be placed in the discharge of either the heating or cooling unit. 4. IMPORTANT: If atomizing spray type humidifier is used, it must be installed downstream from the air filter. If furnace opening cannot be enlarged to required size, a transition sheet metal section must be used. Transition must be planned for each job. Reduction should not be more than 4 inches per l...

Dieses Handbuch ist für folgende Modelle:
Luftreiniger - ACB1000 (341.57 kb)
Luftreiniger - ACM1400 (341.57 kb)
Luftreiniger - ACM1600 (341.57 kb)
Luftreiniger - ACM2000 (341.57 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien