Anleitung White Rodgers, modell CSC1000
Hersteller: White Rodgers Dateigröße: 196.36 kb Dateiname: 8abbd3cc-3f87-4f5e-ba38-6e75ff319c16.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
White-Rodgers is a division PART NO. 37-6336A of Emerson Electric Co. Replaces 846-0273Printed In U.S.A. 0102 RULES FOR SAFE 1. Read the Owners Manual and the Rules for Safe INSTALLATION AND OPERATION Operation carefully. Failure to follow these rules and Please read instructions before installing and using the Elec-instructions could cause a malfunction of filter or tronic Air Cleaner. This will help you obtain the full benefit from unsatisfactory service. the Electronic Air Cleaner you have selected. 2. Follow a regular service and maintenance schedule for efficient operation. s! WARNING s! WARNING Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to installation. Do not use this apparatus in an explosive atmosphere. Failure to do so could result in serious personal injury or death. ELECTROCUTION HAZARD Shut off power at fuse panel before servicing. Failure to do so could result in serious personal injury or death. s! WARNING Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, utility connections and potential hazards. Installation should be performed only by a qualified service provider. Failure to do so could result in reduced performance of the unit, serious personal injury or death. s! CAUTION CABINET AND CELLS MAY CONTAIN SHARP EDGES. Use care when servicing unit or handling cells. Failure to do so could result in minor personal injury. Specifications CSC1000 Self-Contained Ceiling Hung Electronic Air Cleaner Weight: 66 lbs. Model: CSC1000 Shipping Weight: 76 lbs. Voltage: 120 VAC, 60 Hz. Efficiency: Efficiency varies with fan speed approximately 96% Watts HI-speed: 240 at low speed and 87% at hi speed. Fan Speed: Variable 200 to 1000 CFM NOTE: Unit must run for one full hour after installation. This will Dimensions: 28”H x 28”W x 111/2”D allow the collecting cells to reach peak efficiency. Basic Tools Required Screwdriver, Rule or Tape Measure, Drill HOW THE AIR CLEANER WORKS The enclosed fan circulates the air through the bottom of the electronic air cleaner and out through the four outlet grilles. The ionizing section of the collecting cell contains many fine ionizing wires that charge the incoming airborne particles. The charged particles move into the collecting plate area and are trapped to the plates (like a magnet attracts and collects iron filings). The cleaned air is then drawn through a charcoal filter to assist in removal of unpleasant odors. The cleaned and purified air is discharged to recirculate through your building. White Dust (Lint) An Electronic Air Cleaner is designed to collect two major types of contaminants: A Irritants (Pollens, Spores, Molds, Bacteria, etc.) and A Black Soiling Contaminants (Dirt and Smoke particles). The residue on the collecting plates of an electronic air cleaner is black, indicating it is removing dirt from the air stream. After installing an air cleaner you may notice white dust (typically, long linty particles or fibers – from carpets, cotton materials or drapery fabrics). This material is not collected by the air cleaner because it does not contain the irritants or soiling contaminants listed above or settles out of the air before reaching the air cleaner. The presence of white dust does not indicate an air cleaner requires service. Table of Contents Rules for Safe Installation and Operation . . 2 How the Air Cleaner Works . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Operation/Maintenance . . . . . . . . . . . . . . . . 4 Technical Repair Guide. . . . . . . . . . . . . . . . 5 Repair Parts. . . . . . . . . . . . . . . . . . . . . . . . . 7 Wash Reminder. . . . . . . . . . . . . . . . . . . . . . 8 Carbon (Charcoal) Filters Odors are gas molecules, not particles. They cannot be removed by an Electronic Air Cleaner or by any other filtration media designed to remove airborne particles. However, some gases can be absorbed by an activated carbon filter or diluted with fresh outdoor air. When odors are present, the addition of charcoal filters will neutralize odors, such as cooking odors, pet odors, cigar and cigarette odors, ozone, etc. Optional charcoal filters are available for your Air Cleaner. Refer to the parts list for the charcoal filter part number for your Air Cleaner. Charcoal filters require replacement. They cannot be washed. While there is no rule of thumb for how often they should be changed, you can use your best judgement based on the odors you perceive in your environment. 2 Clean Air Out DIRTY AIR IN FIG. 1 Illustration of Air Cleaning Process Clean Air Out Charcoal Filter Reduces Odors Collecting Plates attract and hold dirt particles like a magnet Ionizing wires give dirt particles a positive charge Prefilter Screen INSTALLATION PLACEMENT The installer must be qualified to make approved electrical connections and a safe ceiling installa...