Before removing any wiring from your existing thermostat, its wires must be labeled with their terminal designations. Ignore the color of the wires since they may not comply with any standard. PSP711CC SERIES SMART TEMP® ELECTRONIC THERMOSTAT HEAT OFF COOL SET SUNDAY WEEKDAY PROGRAM SET DAY/TIME PM Installs Easily Set Day and Time Choose Heat or Cool Easy as 1–2–3 Complete, Easy To Read INSTALLATION AND OPERATING INSTRUCTIONS CONNECTING THE WIRES 5. Wires must be trapped between black clamp and brass terminal. 6. Securely tighten all 7 electrical terminal screws. COMPATIBILITY FEATURES INSTALLATION Please read all instructions carefully before beginning installation. TOOLS REQUIRED . #1 Phillips screwdriver (small) . Drill with 3/16-in. (4.8mm) bit . Wire stripper/cutter THERMOSTAT LOCATION On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below. 1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often. 2. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, television, radiator, register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall. 3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window. 4. Do not locate in a damp area. This can lead to corrosion that may shorten thermostat life. 5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open door. 6. Do not install the unit until all construction work and painting has been completed. WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc. Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save for future reference. The PSP711CC can be used with most single stage 24 volt gas, oil or electric heating and air conditioning systems, single stage heat pumps, or gas millivolt heating systems. It cannot be used with 3 wire zone valves, 120 volt heating systems, or multi stage heat pumps. Ask your dealer for other LUXPRO thermostats to control those systems. . Small elegant design . Exclusive LUX Speed Dial® . EL Illuminated Display . Comprehensive Graphical Filter Monitor . 7 Day Programming . Energy Star Compliant . 4 Periods Per Day . Clean Cycle® (Patent No. 6,988,671) Independently Programmable Fan . Nonvolatile Memory For All Programs And Settings . Temporary Temperature Override . Temperature Hold . Keyboard Lockout . F/C Temperature Display . 12/24 Hr Clock Display . Adjustable Temperature Differential / Cycle Rate . User Temperature Offset / Calibration . 5/2 minute selectable minimum Run/Off time provides short cycle and compressor protection C A U T I O N The PSP711CC is protected against normal static electric discharges. To minimize the risk of damaging the unit in extremely dry weather, touch a grounded metal object before touching your thermostat. REMOVING THE OLD THERMOSTAT 1. Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. 2. Remove cover from old thermostat. Most are snapon types and simply pull off. Some have locking screws on the side. These must be loosened. 3. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identification. Remove and label wires one at a time. Make sure the wires do not fall back inside the wall. 4. Loosen all screws on the old thermostat and remove it from the wall. 4. Hold the base against the wall. Route the wires through the hole below the terminal block. Position the base for best appearance (to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided. G Y W RH RC B* O* SINGLE STAGE HEAT PUMP SYSTEM 24 VOLT HEAT TRANSFORMER CHANGEOVER HEAT CHANGEOVER COOL FAN *"B" OR "O" BUT NEVER BOTH HEAT PUMP 120 VAC ADD JUMPER JUMPER COMPLETING YOUR INSTALLATION 7. See Setup Options to configure jumpers. 8. Install two new Energizer or DURACELL "AA" size alkaline batteries at this time. For instructions, see BATTERIES/MAINTENANCE. 9. Install your PSP711CC on its base. To do this hang the top of the unit by the tabs on the base, then snap the bottom of the unit into place. Do not use unnecessary force. If the body does not snap into place easily, re...