Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Air-O-Swiss, modell AOS 2055D

Hersteller: Air-O-Swiss
Dateigröße: 3.1 mb
Dateiname: AOS_2055D_ManualUSA08_EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Water quality maintenance An Ionic Silver Stick© (26) keeps the water free of harmful bacteria. The anti-microbial action of silver is used. The Ionic Silver Stick releases silver ions in the water over a long period (approx. one year). It‘s self-regulating and maintenance-free. Look at picture 26 for the position of the ISS in the base part of the unit. Switch off the unit first. Contact your local retailer or check our website for re-order information. Lifecycle indicator Your appliance comes with a lifecycle indicator on the back of the upper part for changing the Ionic Silver Stick®. To remind yourself of when you put the ISS into operation, please cross the current month on the indicator and write the current year on the line provided (27). 26 27 11 en ACID 2 1 3 28 28 32 35 30 33 34 36 31 12 en Cleaning the water tank and base (every 2 weeks) • Lift the water tank out of the unit, open the water tank cap and clean the tank (37 – 39). • Lift the upper part of the unit off the base and remove the Ionic Silver Stick® (40). • Use AIR-O-SWISS EZCal custom cleaning and descaling agent only to remove deposits from the water base regularly (41). There is a sample of EZCal included in the packaging of your humidifier. Instructions for using are on the packet. Rotate the disc assembly a few times by hand (41) to clean the mineral deposits on the humidifying discs. Only use 1 packet for 32 oz of water. Do not change the ratio. Do NOT run the unit when using EZCal. This can cause damage to the product and voids the warranty. Thoroughly rinse the base with potable water after using EZCal and make sure no EZCal residues remain in the base. • Empty the water base (42), remove the disc assembly (43) and rinse (44). • Remove deposits from the base using a plastic or wooden brush (45). 37 38 39 40 Cleaning the humidifying discs (every 4 weeks) A thin film of lime scale on the discs actually increases the humidity output! To clean, unscrew the individual humidifying discs from each other. Rotary locks (toothed wheels) can be easily removed using the multifunctional fragrance container (46). Next, the discs can be washed individually (47 – 48). For best results use EZCal custom cleaning agent for AIR-OSWISS products. Refer to section «Cleaning the water tank and base» for more information of how to use EZCal. • The toothed wheel can only be assembled in one position. After cleaning, reassemble the appliance in the reverse sequence. Note: rotary locks have two rest positions. Warning: Do not overtighten! 13 en 30 min 140°F / 60°C 41 42 43 45 44 46 47 48 49 en Storing the appliance for extended periods Clean the appliance as described earlier and allow to dry thoroughly.Preferably store the appliance in its original box, in a dry place away from high temperatures. Legal notice The humidifier is cULlisted. Subject to technical change. The instructions for use are protected by copyright © PLASTON AG. Accessories Contact your local retailer or check our website airoswiss.net for reorder information. Customer Service Customer Service (USA) 18003360326 Trouble shooting Technical specifications Electrical voltage 120 V / 60 Hz Power consumption 20 W Humidity output up to 3.25 gallons / 24h Suitable for rooms up to 750 sq ft / 70 m2 Dimensions 14.2 x 14.2 x 14.2 in 36 x 36 x 36 cm Weight (empty) 13 lbs / 5.9 kg Operating noise level < 25 dB(A) Accessories Ionic Silver Stick® Problem Possible cause What to do Appliance does not work Power plug not inserted Connect power plug to the outlet Turn rotary switch to position ON No water in the water tank Fill with water Brushing noise Disc assembly is not correctly inserted Insert the disc assembly correctly in the water base. Discs warped Replace discs No humidification No water in the water base Fill the water tank 1 General Humidifier Questions Q. Why isn’t there enough moisture in my room? A. How often do you run the unit? If the unit is only run at night, then during the day the moisture level will drop if moisture is not constantly added to the air. A. Do you leave your door open or closed when the unit is running? a. By leaving the door open, this allows moisture to leave the room and go into other areas of the house. If you would like the moisture to stay within one specific room you should consider closing the door while the unit is running. b. Wood, leather, carpet, curtains, and other types of fabric soak up a lot of moisture, thus not leaving enough moisture for the air. If the window is left open, then this allows moisture to escape the room. Another factor is a lot of times the unit is placed next to a heating device. The idea is that the air blowing into the room will quickly place moisture around the room. Unfortunately, this concept does not work because the hot air coming out of a vent will soak up most of the moisture, and none of the air within the room will receive any. Q. How much moisture do I need in my room? A. Suggested ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien