Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Air-O-Swiss, modell AOS 7131

Hersteller: Air-O-Swiss
Dateigröße: 672.74 kb
Dateiname: AOS_7131_ManualUSA06_EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Your humidifier controls automatically the humidity level according to desired setting. If the air is too dry, the humidifier will automatically switch on. As soon as the desired humidity level is reached, it will switch off. Unpacking • Carefully remove the humidifier from the box. • Remove the plastic bag from the humidifier. • Observe the information given on the rating plate about the voltage. • Use the original packaging for storing the appliance if you do not use the humidifier all year round. en Mist outlet (rotating) Cover Water tank Evaporation chamber Demineralization cartridge Water tank cap Brush Water base Main body Control panel Water level sensor Membrane ISS (optional) Power plug Air inlet Filling the tank Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The red light comes on indicating tank is empty. • Make sure that no foreign objects are in the water tank. • Take off the water tank cap to fill the tank with water (11). Fill the tank with clean, cold water from the tap (12). Close the cap of the water tank securely, place the water tank and then the cover onto the base (13). The water is now running from the tank into the base. • Do not pour water into the mist outlet of the appliance (14). • Insert the plug into the socket and switch on the appliance using the on/off switch (15). The green light comes on. If you see the red light that displays that the water tank is empty. Use of additives Water additives (ethereal/essential oils, fragrances, eucalyptus, water conditioners etc.) must not be used! Even a small amount can cause cracks in the material. The material isn’t made for the use of such additives. One drop is enough to damage the tank and as a consequence the unit. Any use of such additives will void the manufacture’s warranty. 13 10 en 14 11 15 12 O/ I Operation 7131 Water quality maintenance An Ionic Silver Stick© (16) keeps the water free of harmful bacteria. The anti-microbial action of silver is used. The Ionic Silver Stick releases silver ions in the water over a long period (approx. one year). It‘s self-regulating and maintenance-free. Look at picture 16 for the position of the ISS in the base part of the unit. Do not touch the water in the base during operation! Switch off the unit first. Contact your local retailer or check our website com for reorder information. en O/ I B A C A) On-off switch and regulation of mist output Turning the right-hand rotary switch clockwise switches the appliance on and at the same time regulates the mist output from low to high. B) Hygrostat (setting the humidity level) The desired humidity level can be set by turning the lefthand rotary switch clockwise. A relative humidity of between 40% and 60% is recommended. The accuracy of the measurement is +/- 5%. As soon as the humidity exceeds the desired setting the appliance switches off. The appliance does not switch off if the rotary switch is turned all the way to the right as far as the arrow symbol. This activates the continuous operation function. C) Empty indicator As soon as the tank runs out of water, the red empty indicator lamp turns on and an alarm is sounded. Please read the chapter “Filling with water” for more information. Replacement of the demineralization cartridge Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! The water tank is equipped with a demineralization cartridge. This cartridge has to be replaced every 2 – 3 months. If the water is very hard, it may be necessary to replace the cartridge earlier. White dust around the device is a sure sign that the cartridge needs replacing. Please note white dust is not harmful. If white residue still forms around the device after a new cartridge has been inserted, please make sure that the water you are using is untreated. If the water flows through a decalcification system (natrium added to remove calcium) in the building before it is used in the humidifier, salt can precipitate as white dust around the device. Option A: replace the resin • Remove the cover (Caution: the mist outlet is loose!). Remove the water tank from the base and unscrew the water tank cap (17). • The demineralization cartridge is attached to the inside of the tank cap. Unscrew the cartridge from the cap by turning it counter-clockwise (18). Important: do NOT dispose of the water tank cap! • Open the cartridge (19). • Throw the content into the waste (Attention! Disposed resin can make the floor slippery!) (20). • Pour the resin into the cartridge (22). (Attention! Make sure that no granules get in the center of the cartridge. It can clog the unit). • Close the cartridge (24). • Screw the cartridge on the water tank cap (25). • Screw the cartridge on the bottom side of th...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien