Anleitung Zusammenfassung
The computer While an error code appears in the display, all face plate buttons are inoperable except the SELECT but- monitors electronic components I and circuits for correct opera-_l-I-I ton. SELECT remains operational so the service pertion, If a malfunction occurs, an son can make the MANUAL INITIATED ELEC L error code appears in the face-TRONIC DIAGNOSTICS (below) to further isolate _late display, the defect, and check the water meter. POSSIBLE DEFECT MOST LIKELY _ _ LESS LIKELY CODE Err1, Err3, motor inoperative / wiring harness or connection to switch / position switch / valve defect causing Err4 hiplh torque Err5 faceplate timer (PWA) PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug transformer from outlet 2. Correct defect 3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected. MANUAL INITIATED ELECTRONICS DIAGNOSTICS I To enter diagnostics, press the SELECT button and hold for three seconds. You will see the following display, showing valve cycle position, position switch status (open or closed), and turbine operation. turbine count (water valve position indicator flowing) _N_ i l uuoq 22 I "_"_ /_'7,n I position switch turbine count (no indicator (open) water flowing) TURBINE OPERATION: If no water is flowing through the softener, the turbine indicator displays three zeros. When water is flowing, the flow bar scrolls across the display, and a 000 to 199 count repeats for each gallon of water passing through the turbine. To check for positive operation of the turbine if zeros are shown, open a nearby soft water faucet and observe the turbine count and flow bar. If you don't get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, unhook the in and out plumbing and check the turbine for binding. ( POSITION SWITCH _ -" -T. _" SENSOR HOUSING I_-TURBINE _TURBINE SUPPORT AND SHAFT VALVE OL POSITION SWITCH STATUS: With the valve in service, or any of the recharge cycles, the switch indicator will show open -'_-. While the valve is rotating from 1 position to another, the indicator will show the switch closed -"---. A defect is probable if indications vary from this pattern. 5-2 Problems, Questions? Call 1-800-426-9345 Kenmore Water Line _i_ii_i!_i_i SECTION 5 ]_i!_!!_i_!iiiiiii!_ SERVICE TECH. INFORMATION A. TROUBLESHOOTING VALVE POSITION INDICATORS: Depending on the valve position, the following indicators show in the display: INDICATOR VALVE POSITION S .......................... service F .......................... fill BR ........................ brining/brine rinse BW ........................ backwash R .......................... fast rinse When the valve is rotating from one cycle to another, both indicators flash. For example, if the valve is in transition between fill and brining, both Fill and Brine flash. Upon reaching brining position, Fill goes off and Brine is on steady. The time display shows the minutes of the cycle remaining. NOTE: If the faceplate is left in a diagnostic display (or a flashing display when setting times or hardness), present time automatically returns if a button is not pressed within 4 minutes. To return to the diagnositc display, repeat step 2. OTHER 1NFO_TION: While in this diagnostic screen, the following information is available and may be beneficial for various masons. This information is retained by the computer from the first lirne electrical power is applied to the faceplate. ... Press [] to display the number of days this face plate has had electrical power applied. ... Press [] to display the number of regenerations initiated by this faceplate since the SR code number was entered. _1 Press valve and eration, the ON/OFF-HOLD to each position position indicators or to possibly button to advance the and observe the switch to verify component opisolate a defect. _1_ Press until and ... hold the SELECT button for 3 seconds ...SR29 shows 71--I_--7 for UltraSoft 250 I"-7n ...SR33 shows for UltraSoft 275 I b,-dd This code identifies the softener nominal capacity size. If the wrong number shows, the softener will operate on incorrect programming. Do the following as needed. SR29 or SR33 does show--Press the sELECT but ton to return to the present time display. To change SR number --Press the UP or DOWN button until the correct SR code shows. Then, press the SELECT button and reset the timer ... page 1-3. TIMER PWA REPLACEMENT: Be sure the valve is in service position when replacing the timer PWA (observe valve cycle indicator). If, after installing and programming the replacement timer PWA, the valve isnot in service position, do the following to assure correct cycle orientation, or timing, between the faceplate and valve. Use the MANUAL ADVANCE procedures, page 5-4. With the RECHARGE NOW button, advance through the recharge cycles until the valve stops i...
Dieses Handbuch ist für folgende Modelle:Wasserfilter - ULTRASOFT 250 625.38827 (1.27 mb)