A nearby shutoff valve is convenient. Most sinks already have shutoff valves on the supply pipes. Cold Water supply valve Tubing insert Tubing adapter Compression nut Water in Water out Tubing Insert Mounting screw (2) Nut Tubing Locate the drinking water system on the cold water supply pipe, under the kitchen and/or bathroom sink, to filter the cold drinking water. Model GX1S04C only Use to connect the tubing Turn off the cold water supply and attach saddle valve as shown in illustration at right. DANGER: To protect yourself from serious injury or fatal shock, use a battery-powered hand drill only to make the hole. DO NOT USE AN ELECTRIC DRILL. Close the water supply valve by turning the handle clockwise. Open the main water supply valve and several house faucets to purge Optional water supply connection (using saddle valve)* Pre-drill 1.4. hole Seal—make sure the seal is in place Clamp X Nut (2)—not required if holes in clamp are threaded Valve Handle Tubing adapter Tubing insert Clamp Z *For 1/2" OD or larger metal tubing only. Feed Water Supply Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting. For new home installation using standard plumbing fittings, see first two illustrations below. A typical installation for existing homes using the saddle valve is shown in third illustration below. A. PREFERRED INSTALLATION 21 Turn off the cold water supply. Complying with plumbing codes, install a fitting on the cold water pipe to adapt 3.8 . OD tubing. A typical connection is shown in illustrations at right (parts not included). Make sure a water supply valve is used. Preferred water supply connection (using compression fitting) Insert (not included) Cold water pipe 3.8. tubing to inlet Ferrule Water supply valve Typical location Cold water B. OPTIONAL HOME INSTALLATION Where codes permit *For 1/2" OD or larger metal tubing only. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts. 1 32 air from the system. Close faucets when water runs smoothly. Snug valve into bracket DO NOT OVERTIGHTEN Some threads should be visible Compression nut Rubber gasket Step-by-step installation instructions. Faucet Installation Be sure there is room underneath the sink to make the needed connections. Select one of the following places to install the faucet: —IN an existing sink spray attachment or soap dispenser hole. —IN a hole to be drilled in the sink top. —IN a hole to be drilled in the countertop, next to the sink. NOTE: Looking at second illustration at right, be sure the faucet base will fit flat against the surface at the selected location so the gasket will seal. If drilling is needed, make a 3.4 . dia. hole. Be sure to use the proper 1 procedure for drilling porcelain or stainless steel. Special drill bits may be needed. 2 Place small gasket, base and large gasket (in that order) onto the faucet stem. Next, place lock washer and hex nut onto faucet stud. Insert tubing insert into tubing adapter. Securely tighten to faucet stud. Feed the length of 3.8 . OD tube from the bottom, up through the 3 4 mounting hole. Connect to the tubing adapter as shown in second illustration, tightening the compression nut securely. 5 Remove the short shipping tube and insert the spout into the faucet body. Rotate spout into place. 6 Lower the faucet assembly into place on the underside of the mounting hole. Place the mounting bracket above the lock washer. While holding the mounting bracket in place, securely tighten the hex nut. Tubing adapter Sink Base Lock washer Faucet Lever Spout Faucet stud Small gasket Large gasket Mounting bracket Hex nut Tubing insert ASSEMBLED Compression nut 3/8. tubing, (run to Filter outlet) Compression nut Tubing adapter Tubing insert Mounting Bracket to Cabinet Wall The bracket can be used as a template for marking the location of the mounting screws. When determining the location of the bracket make sure you leave 1-1.2 . to 2. of free area under the sumps to allow for sump removal and enough space on either side to make the tubing connections. Tubing Connections—Compression Style (Models GX1S04C and GN1S04C) Mounting bracket Run the length of 3.8. tubing, connected to the bottom of faucet, 1 to the filter system outlet. Allow enough slack in the tubing so the unit Mounting (inlet) screws can be easily removed for filter changes. Measure and cut the end of the tubing square. Slide a compression nut onto the end of the tubing and push a tubing 2 insert into the tubing. 3 Connect the tubing and tighten the compression nuts securely. 4 Repeat the preceding steps to connect a length of tubing between the filter system inlet and the water supply/saddle valve (illustration in the Installation Overview section). Tubing connector (outlet) Tubing connector Sump 2-3.4. 1-1.2. to 2. Tubing Connections—Push-In S...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien