Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung GE, modell 268

Hersteller: GE
Dateigröße: 2.74 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The words “Regeneration Time” will scroll through the banner display. To change the regeneration time press and hold the UP or DOWN button until the desired regeneration time is displayed. Press SET to lock this time into memory. NOTE: When the controller is set up for a twelve hour clock a PM indicator will illuminate when the displayed time is in the PM hours. There is no indicator for the AM times. Level I Programming Rev A Level II Programming Level II program parameters are those parameters used to fine-tune a conditioners operation. These are accessible by pressing and holding the UP and DOWN buttons until the display goes blank. Then release the buttons. Calendar Override is the first Level II parameter displayed. Level II program parameters include: 268 Conditioner Operation Type 263 Filter Operation Type CALENDAR OVERRIDE CALENDAR OVERRIDE SALT AMOUNT REGEN SU CAPACITY K GRAIN REGEN MO HARDNESS GPG REGEN TU SELECT LANGUAGE REGEN WE CLOCK MODE REGEN TH UNITS OF MEASURE REGEN FR INJECTOR SELECTION* REGEN SA BACKWASH 1 CAPACITY GAL SLOW RINSE SELECT LANGUAGE FAST RINSE 1 CLOCK MODE BACKWASH 2 UNITS OF MEASURE FAST RINSE 2 BACKWASH OPERATION TYPE 268* FAST RINSE SERVICE INTERVAL OPERATION TYPE 263* CHLORINE GENERATOR SERVICE INTERVAL CHLORINE GENERATOR *View only. Level II parameters will, in almost all cases, be preset to meet your configuration needs. The predefined system number will preprogram all of the Level II parameters to the selected default values. • Setting the Calendar Override Calendar Override allows the programmer to set the maximum days between regenerations. A setting of 0 (zero) means the calendar override is disabled. To change the calendar override, press the SET button while the words “CALENDAR OVERRIDE" appear on the banner display. The blinking digit can be changed to the desired numbers of days. To lock in the parameter, press the SET button. WARNING: Setting days between regeneration to zero will cause the system to not regenerate. This setting is used for selecting regeneration on specific days or to use with a remote regeneration input. See below. Level II Programming Rev A NOTE: Regeneration on specific day is used to provide regeneration when water demands are not steady. Example: If the weekdays have low usage and the weekend is high, then regeneration every three days will not meet the requirements. The calendar override days between regeneration must be set to zero to enable regeneration on specific days. • Setting Backwash Days (263 filter only) The 263 filter controller can be programmed to regenerate on an elapsed time period (calendar override) or by the day of the week. If you would like to regenerate on specific days select a 0 (zero) for the calendar override setting, the 263 filter will prompt you to select the days of the week in which you would like the unit to regenerate/backwash. For example, the unit could be programmed to regenerate every Monday, Wednesday and Friday. • Setting the Salt Amount (268 softener only) Is selected by the system model number. Your Ultramax Water Treatment Dealer enters the model numbers based on the specific application requirements. • Setting Capacity Softener Default Capacity Setting The default capacity setting is accurately calculated when the model number is entered by the factory. The capacity can be changed to operate "custom systems". Contact your Ultramax Water Treatment Dealer before adjusting the capacity setting. Default capacities are shown in Table 1. Filter Capacity Filter capacity is set in gallons or cubic meters. It is programmable from 100 to 14000 gallons or 1 to 140 cubic meters of capacity. Press the SET button and the digits will begin flashing. Change the capacity by using the up and down arrows to adjust the setting. To accept the setting, press the SET button. NOTE: (Conditioners only) A different model number must be selected to change the default capacity and salt dosage. • Setting the Hardness (conditioner only) Hardness is set in grains per gallon (gpg) or parts per million (ppm) and should be programmed to the total hardness level of the incoming water supply. Press the SET button to make the display flash. Use the UP and DOWN buttons to adjust the hardness setting. Press the SET button when the desired setting has been reached. • Setting the Language Level II Programming Rev A The controller is capable of displaying 6 different languages. They are as follows: 1 = English 2 = Spanish 3 = French 4 = Italian 5 = Flemish 6 = German Press the SET button and select the desired language using the UP or DOWN buttons. Press the SET button to accept the selection. •Setting Clock Mode The controller can be programmed to operate with a 12- or 24-hour clock. Program the clock mode to "12" for a 12-hour clock or "24" for a 24-hour clock. When the controller is programmed as a 12-hour clock the PM indicator will illuminate during the PM hours. There is no AM indicator. •Setting Units of Measure The controller can...

Dieses Handbuch ist für folgende Modelle:
Wasserfilter - 263 (2.74 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien