Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Lochinvar, modell TST2313

Hersteller: Lochinvar
Dateigröße: 6.65 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


This item is available in all modes. -67 to 149°F (-55 to 65°C) BOB. sup j Lj g* occ • Boiler Supply - Current boiler supply water temperature as measured by the boiler supply sensor. This item is available in all modes. 14 to 266°F (-10 to 130°C) BOB. ir r T TAflQ 1 J J OCC D1 E1 F1 • Boiler Target - Boiler target temperature is the temperature the control is currently trying to maintain at the boiler supply sensor +/-1/2 of the differential. This item is available in all modes. —, 14 to 266° F (—, -10 to 130°C) BOR. - gif occ • Boiler Return - Current boiler return water temperature as measured by the boiler return sensor. A boiler return sensor must be installed to view this item. This item is available in all modes. 14 to 266°F (-10 to 130°C) 55-f occ • Delta T - Current difference in temperature between the boiler supply sensor and the boiler return sensor temperatures. A boiler return sensor must be installed to view this item. This item is available in all modes. 0 to 252° F (Oto 140°C) BOH. nnp uul 1 A • Boiler 1 Hours - The total running time of boiler 1 since this item was last cleared. To clear this item, press the a and y arrow button simultaneously while viewing this item. This item is available in all modes. Oto 1999 hr BOB. nnn uul 2 A • Boiler 2 Hours - The total running time of boiler 2 since this item was last cleared. To clear this item, press the A and V arrow button simultanously while viewing this item. This item is available in modes 1 to 3. Oto 1999 hr BOH. n n T UUJ» 3 A • Boiler 3 Hours - The total running time of boiler 3 since this item was last cleared. To clear this item, press the A and V arrow button simultanously while viewing this item. This item is available in mode 1. 0 to 1999 hr BOIL nn3 uul 4 A • Boiler 4 Hours - The total running time of boiler 4 since this item was last cleared. To clear this item, press the A and v arrow button simultanously while viewing this item. This item is available in mode 1. Oto 1999 hr BOH. nng uul 5 A • Boiler 5 Hours - The total running time of boiler 5 since this item was last cleared. To clear this item, press the A and v arrow button simultanously while viewing this item. This item is available in mode 1. Oto 1999 hr BOB. n n 3 uul 6 A • Boiler 6 Hours - The total running time of boiler 6 since this item was last cleared. To clear this item, press the A and v arrow button simultanously while viewing this item. This item is available in mode 1 only. 0 to 1999 hr 24 View Menu (2 of 2) Display Description Range sou. nn j uul 7 A • Boiler 7 Hours - The total running time of boiler 7 since this item was last cleared. To clear this item, press the A and v arrow button simultanously while viewing this item. This item is available in mode 1 only. Oto 1999 hr BOIL n n □ uul 8 A • Boiler 8 Hours - The total running time of boiler 8 since this item was last cleared. To clear this item, press the A and v arrow button simultanously while viewing this item. This item is available in mode 1 only. Oto 1999 hr BOIL flfll uul 9 A • Boiler 9 Hours - The total running time of boiler 9 since this item was last cleared. To clear this item, press the A and v arrow button simultanously while viewing this item. This item is available in mode 1 only. Oto 1999 hr Adjust Menu (1 of 4) Display Description Range Actual Setting ROOM "in-F IU occ D1 • Room Occupied - The desired room air temperature during the occupied period. This item is only available if the External Input/ Stand Alone DIP switch is set to Stand Alone. 35 to 100°F (2 to 38°C) Default = 70°F (21 °C) mow 55' UNOCC D1 • Room Unoccupied - The desired room air temperature during the unoccupied period. This item is only available if the External Input/ Stand Alone DIP switch is set to Stand Alone. 35 to 100°F (2 to 38°C) Default = 65°F (18°C) n. m U' IU ► F1 • External Input Signal - Selects the range of the external input signal. This item is only available if the External Input/ Stand Alone DIP switch Is set to External Input. 0:10,2:10 Default = 0:10 n* u ► F1 • Offset - Sets the temperature offset used in calculating the boiler target temperature with an external input signal. This item is only available if the External Input/ Stand Alone DIP switch is set to External Input. -10 to 10°F (-6 to 6°C) Default = 0°F (0°C) —OFF BST D1 • Boost - The amount of morning boost. This item is only available if the External Input/ Stand Alone DIP switch is set to Stand Alone. OFF, 0:20 to 8:00 hr (5 minute increment) Default = OFF Bornai mode i i B1 • Mode - Selects the staging mode of operation. 1 (9 Boil), 2 (4 Boil 4 Pmp), 3 (4 LoHi), 4 (3 LoHi 3 Pmp), 5 (3-3 Stg), 6 (2-3 Stg 2 Pmp), 7 (2-4 Stg), 8 (1-4 Stg 1 Pmp) Default = 1 sou. flu 1 B1 • Boiler 1 - Selects whether or not boiler 1 is operational. This item is available in all modes. Au (Auto), OFF Default = Au 25 Adjust Menu (2 of 4) Display Ru Ru...

Dieses Handbuch ist für folgende Modelle:
Wasserfilter - INS7141 (6.65 mb)
Wasserfilter - INS7162 (6.65 mb)
Wasserfilter - MP2 (6.65 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien