Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung HoMedics, modell Restore RWS-1FL

Hersteller: HoMedics
Dateigröße: 1.05 mb
Dateiname:
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Select the proper number of cups per day by pushing the CUPS PER DAY button until the desired usage is selected. • For your reference in setting your consumption level a full pitcher capacity is 8 cups. • If your consumption changes you can change the setting at any time and the filter life will automatically adjust. • A filter will last approximately 2 months with average household use. NOTE: For maximum efficiency do not purify more than 2 gallons per day. 8 Maintenance To Clean • Pour out water. • To ensure that the UV lamp assembly introduces the proper dose of Ultraviolet light into the water the lamps protective outer quartz sleeve is to be cleaned once each month by wiping it with white vinegar and then rinsing. (fig. 7) • Unplug adapter and wipe with a moist cloth. Dry before use. • Hand wash all parts, except the adapter, with mild dish soap before use or after storing for an extended period of time. • Do not use abrasive cleaners or scrubbers. • Your Restore™ Water System is not dishwasher safe. To Store • Follow cleaning instructions above. • Unplug the adapter from the outlet. • Retract adapter power cable. • Dry all standing water. • Store in original box. fig. 7 Caution: Restore™ Water System is not dishwasher safe. Caution: All servicing of this water system must be performed by authorized HoMedics service personnel only. 9 FCC Notice Note - This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note - This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Note - The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment. 10 Troubleshooting The UV will not activate Please make sure the following steps have been taken: • The valve is in the PURIFY position. • The Adapter is plugged into a functional 3 pronged outlet. • The Adapter cord is firmly seated in the pitcher base. • The reservoir and lid must be installed and firmly seated. • The Adapter battery is installed correctly. See adapter battery door for instructions. • Once the above steps have been taken, press and hold the PURIFY button on the Adapter The REPLACE FILTER indicator is blinking In this condition the filter timer has expired indicating the filter should be replaced. • First follow steps to replace the filter in the Getting Started section. • To reset the timer, and turn off the blinking indication, hold the button down for 5 seconds. • The timer now begins the timing duration prescribed by the programmed Cups per Day setting. See the User Interface section for setting the Cups per Day. 11 Performance Data Sheet HoMedics Restore™ Water System-Model: RWS-100 Replacement Filter-Model: RWS-1FL Distributed by HoMedics, Inc. 3000 Pontiac Trail, Commerce Township, MI 48390 This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. Testing was performed under standard laboratory conditions, actual performance may vary. SubstanceInfl uent Challenge ConcentrationMaximum Permissable ConcentrationAverageActual ReductionNSF 42 - Aesthetic EffectsChlorine- Taste and Odor2 mg/L ± 10%1 mg/L98.9% Zinc10 mg/L ± 10%5 mg/L86.2% NSF 53 - Health EffectsBenzene0.015 mg/L ± 10%0.005 mg/L94.4% Cadmium - pH 6.50.03 mg/L ± 10%0.005 mg/L91.8% Cadmium - pH 8.50.03 mg/L ± 10%0.005 mg/L89.9% Copper - pH 6.53 mg/L ± 10%1.3 mg/L89.7% Copper - pH 8.53 mg/L ± 10%1.3 mg/L77.9% Lindane*0.002 mg/L ± 10%0.0002 mg/L99% Mercury - pH 6.50.006 mg/L ± 10%0.002 mg/L96.2% Mercury - pH 8.50.006 mg/L ± 10%0.002 mg/L94.3% Tetrachloroethylene0.015 mg/L ± 10%0.005 mg/L93.2% Toluene3 mg/L ± 10%1 mg/L99.4% *Compliant for Lind...

Dieses Handbuch ist für folgende Modelle:
Wasserfilter - Restore RWS-100 (1.05 mb)
Wasserfilter - Restore IB-RWS100A (1.05 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien