Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung Culligan, modell Automatic Water Softeners

Hersteller: Culligan
Dateigröße: 833.11 kb
Dateiname: w-ws-HiFlo3-lit.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Additional reinforcement from continuous fiberglass overwrap. Underdrain design maximizes softener’s capacity, reduces pressure loss. • Softening Media—High quality resin provides stability and uniform size for top performance and long life. • Choice of Cycle Controllers—Regeneration cycle may be initiated by timeclock any or every day of the week. Optional meter starts cycle after preset volume of water has been softened. • Positive Motor-Driven Regeneration Valve–Motor driven piston is reliable under severe water conditions, resists dirt, iron, turbidity. • Automatic Brine Control—Automatically measures the correct amount of brine. A single turn of dial sets correct amount dosage and capacity. • Dubl-Safe™ Brine System—Positive overfill protection. Automatic refill control is backed up by shutoff float valve to minimize chance of overflow. The Culligan Hi-Flo® 3 Automatic Water Softener Applications and Benefits • RO/DI Pretreatment • Apartment buildings, assisted living facilities and hotels—Quality water for laundry, dishwashers, boilers. • Office buildings—For heating plant pretreatment, tenant convenience, general housekeeping. • Restaurants—For dishwashing, cleaning material savings, scale reduction. • Car washes—Quality results, detergent and water heating savings, scale reduction. • Light industry—For process and make-up water, boiler and cooling system pretreatment, general housekeeping. Warranty Culligan® Hi-Flo® 3 water softeners are backed by a limited 1-year warranty against defects in materials, workmanship, and corrosion. The plastic conditioner tank has a 5-year warranty. See printed warranty for details.* Some localities have corrosive water. A softener cannot correct this condition, so its printed warranty disclaims liability for corrosion of plumbing lines, fixtures, or water-using equipment. If you suspect corrosion, your independently operated Culligan dealer has equipment to control the problem. *Culligan will provide a copy of warranties upon request. Options • Regeneration Flexibility—There are several choices for regenerating a Hi-Flo® 3 water softener to meet your requirements. The simple, economical choice is timeclock operation for both single and duplex units. If water usage varies, meter operation is available to signal regeneration immediately or delay regeneration until a pre-set time. Duplex meter operated units may be operated in parallel or on an alternating basis, depending upon your needs. HC-150 5 60 78 21 x 54 24 x 48 HC-210 7 58 76 21 x 69 24 x 48 HC-300 10 65 85 24 x 72 30 x 48 HC-450 15 75 100 30 x 72 30 x 48 Model Continuous* Peak** Softener Brine System Specifications Pressure: 30–120 psig 210–830 kPa Vacuum: None1 Temperature: 40–100°F 4 - 38°C Electrical: 120V, 60 HZ Turbidity: 5 NTU, max.2 Chlorine: 1 mg/L, max.2 Iron: 5 mg/L 1Tank warranty is void if subject to vacuum 2See media specification for details *Flow rate at a 15 psi pressure loss. **Flow rate at a 25 psi pressure loss. ***Dimensions are diameter by tank height. Culligan Commercial @ WorkTM 1-800-CULLIGAN ©2001 Culligan International Co. SL-0090 DCO 992824 Printed in USA (2/01) MOORE PART NO. 46956 “Hey Culligan Man!”® Resin Qty. (Ft3) Flow Rates Pipe Size Hey Culligan Man, Culligan Man, Culligan Commercial @ Work, and Culligan Service Network are trademarks of Culligan International Company. ISO 9001 Certification SM Tank Size*** 2. The contaminants or other substances removed or reduced by this water treatment device are not necessarily in your water. HI-FLO® 3 FULLY AUTOMATIC WATER SOFTENERS SPECIFICATIONS AND OPERATING DATA Single Tank Model Exchange Capacity1@ Salt Dosage Service Flow Rates2 Pipe Size Resin Qty. Softener Tank Size Brine Tank Size Approx. Ship. WeightMinimum Maximum Peak Continuous Flow Press. Drop Flow Press. Drop gr @ lb gr @ lb gpm psi gpm psi in ft3 in in lb g @ kg g @ kg m3/hr kPa m3/hr kPa in L mm mm kg HC-150 100,000/30 150,000/75 78 25 60 15 2 5 21 x 54 24 x 48 540 6,480/14 9,720/34 17.7 172 13.6 103 2 142 530 x 1,370 610 x 1,200 460 HC-210 140,000/42 210,000/105 76 25 58 15 2 7 21 x 69 24 x 48 640 9,070/19 13,600/48 17.2 172 13.2 103 2 198 530 x 1,750 610 x 1,200 290 HC-300 200,000/60 300,000/150 85 25 65 15 2 10 24 x 72 30 x 48 865 12,960/27 19,400/68 19.3 172 14.7 103 2 284 410 x 1,830 760 x 1,200 395 HC-450 300,000/90 450,000/225 100 25 75 15 2 15 30 x 72 30 x 48 1,250 19,440/41 29,160/102 22.7 172 17.0 103 2 426 760 x 1,830 760 x 1,200 570 1 Exchange capacities based on treating water containing 10 grains per gallon (171 mg/L) of hardness (expressed as calcium carbonate), free of color, oil, turbidity and at a service flow rates not exceeding 20 gpm per square foot (49 m3/m2/min) of bed area. These are nominal capacities and will vary with influent water characteristics, temperature, pressure and other factors. 2 Operation of a softener at peak flow rate for extended periods of time may result in a slight reduction of softening capa...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien