Anleitung Zusammenfassung


18 5A. TROUBLESHOOTING Keep this manual with your water softener. If repairs are needed, the service technician must have the information on the following pages For telephone assistance, call toll free, 1-800-426-9345 i WIRtNG SCHEMATIC TRANSFORMER 24VAC 1}0 VAC NC wh 0"*"_"_ POSITIO N SWITCH -0 gm NO ( __ Shield i .... I TURBINE "-'--"'SENSOR J display ON/OFF-HOLD button (Recharge Tonight-Now) SELECT ALWAYS MAKE THESE INITIAL CHECKS FIRST 1. Does the time display show the correct time of day? If display is blank, check power source to the softener, -If time is flashing, power was off' for over 6 hours The softener resumes no[maI operation but regenerations occur at the wrong time, -If an error code (Example: Err 03) shows in the face plate display, go to Automatic Electronic DiagnostiCs 2. Plumbing bypass valve(s) must be in Full Service position. 3_ The inlet and outlet pipes must connect to the softener valve inlet and outlet respectively 4_ Is the transformer plugged into a "live", grounded wall outlet, and is the power cable fastened securely? 5. The valve drain hose must be free of kinks and sharp bends, and not elevated over 8 ft. above the floor' DemandWaterSoftener button DOWN button REMOVETHETOP COVER ANDSALTTANKCOVER 6. Is there salt in the storage tank? 7. Is the brine tubing connected? (See water' flow diagrams), 8. Is the brine valve float set right? (See page 22) 9. Press the SELECT button 2 times to display the hardness setting Be sure it is the correct setting for the househotd's water supply, (Make a hardness test of the raw water' and compare with the hardness setting, Also test a soft water' sample to verify if a problem exists,) Press SEIECT twice more to return the time of day display. If you do not find the problem after' making initial checks, do the Manual Initiated Electronic Diagnostics, and the Manual Advance Regeneration Check, 19 AUTOMATIC ELECTRONIC DIAGNOSTICS The face plate computer' has a self-diagnostic function for the electrical system (except input power and water meter'). The . t '=" ..... computer monitors the electronic {Fj% '= D_ components and circuits for cor-I rect operation. If a malfunction occurs, an error code appears in the face plate display. The chart below shows the error codes that could appear, and the possible defects for' each code While an err'or code appears in the display, all face plate buttons are inoperable except the SEI_ECT button The SELECT button remains operational so the service person can make the Manual Initiated Electronic Diagnostics to further isolate the defect, and check the water meter. CODE Err 01 Err 02 Err 03 Err 04 Err 05 POSSIBLE DEFECT MOST LIKELY __ LESS LIKELY motor inoperative I wiring harness or connection to switch I position switch I face plate face plate motor inoperative / face plate face plate / position switch face plate PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1 Unplug tsansformer 2. Correct defect 3 Plug-in transformer 4. Wait for 6 minutes, The error code will remm • , , , ,, ,, ........... MANUAL INITIATED ELECTRONIC DIAG NOSTICS 1. To enter diagnostics, press and hold the SELECT button until 000 --shows in the display. I TURB1NE SWITCHES] nli='t ,=.=_ l orP 1 WATER METER (A) SWITCH (B) A. The first 3 digits indicate water meter operation as follows: 000 (steady) = Soft water not in use, and no flow through the meter. --OPEN A NEARBY SOFT WATER FAUCET- 000 to 199 (continual) = Repeats display for each gallon of' water passing through the meter. If you don't get a reading in the display, with the faucet open, pull the sensor' from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display, if you get a reading, unhook the in and out plumbing and check the turbine for binding. if the defect was not corrected ,,, , , ,, ,,,,,,,,,,,,, : POSITION SWITCH I..,....-TURBINE I ..._--TURBINE SUPPORT AND SHAFT VALVE OUTLET B* The letter' (P) and dash (or dashes) indicate POSITION switch operation. If the letter' appears, the switch is closed, If the dash shows, the switch is open. Use the ON/OFF-HOLD (Recharge Now) button to manually advance the valve into each cycle and check correct switch operation. 20 SE!_T_ON 5 SERVICE TECH. iNFORMATiON f ! 5A. TROUBLESHOOTING ,,,, ,,, ,,,,.,,, ,,, ,,.......................................... CORRECT SWITCH DISPLAYS VALVE CYCLE STATUS Valve in service, fill, brining, backwash or fast rinse position i Valve rotating from one position to -p i another C. While in this diagnostic screen, the following information is available and may be beneficial for various masons, This information is retained by the computer fiom the first time electrical power is applied to the face plate. --Press [] to display the number' of days this face plate has had electrical power applied, --Press [] to display the number' of regenerations initiated by this face plate since the SR code number was entered. 2_ Press the SELECTbutton and hold ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien