The pilot button ( ) should be held down at least 15 seconds with pilot burning. When the pilot button is released the pilot should continue to burn. -If the gas valve button does not pop up when released, stop and immediately call your service technician or gas supplier. -If pilot does not stay lit, repeat steps 1 through 6. -If pilot will not stay lit after several tries, depress the OFF button ( ), and call your service technician or gas supplier. 7. When lit, depress the ON button ( ). The heater will now fire when water is drawn at a rate greater than the threshold flow rate. NOTE: If main burner should fail to ignite, make sure pilot is burning. If not, repeat lighting steps 1 through 6. TO TURN OFF GAS TO APPLIANCE Depress the OFF button ( ) and close the gas supply to the heater. 6 720 606 518 INFORMATION ABOUT WATER TEMPERATURE The AquaStar 125B LPS and 125B NGS water heaters have a gas control that modulates burner output in response to water flow. Its purpose is to ensure that the hot water temperature will remain steady, although the water flow demand might vary (down to 1/2 gal/minute). The AquaStar 125 B”S” will produce a temperature rise of approximately 90°F at flow rates between 0.5 and 1.8 gallons per minute unless the water has been preheated. If the incoming water is already hot, the burners will modulate accordingly so the outlet temperature will not exceed 140°F. Cold water will have to be mixed in at the faucet to produce comfortable temperatures. Mixing in cold water will produce higher flow rates and will reduce risk of scalding. Note: 105° is the maximum recommended temperature for a hot bath. Handwashing should not be done in water hotter than 112° -and cooler for older adults, young children or persons with sensory loss. Remember that scalding can occur in 20 seconds with 135° water. MAINTENANCE AND SERVICE (see maintenance table on back of manual) Approximately once a year, the AquaStar should be checked and cleaned. To remove the front cover, first remove the incandescent particle tray, then unscrew the central screw located at the bottom of the front cover. Pull main cover out toward you and lift up and out. THE FOLLOWING OPERATIONS SHOULD BE PERFORMED BY A QUALIFIED SERVICE PERSON: Vent System: Should be checked annually. Clean and repair as needed. Water Valve (Part # 8707002393): The water valve on this heater should be serviced periodically. Lubricate component #27 on page 14 with a small amount of silicon, faucet or lithium grease every two years to keep its o rings fresh and pushrod sliding smoothly. Every 3-5 years replace components #27 and #29 on page 14. The frequency will depend on the mineral content of the water and conditions of use or whenever signs of corrosion appear at the gas and water valve joint. Periodically check that the water inlet filter (#34 on page 14) is clean as well. Pilot Flame: The pilot flame should burn with a clean sharp blue flame and should resemble the diagram in Fig 8. If the flame is yellow, or if the pilot knob has to remain depressed for a long time in order to keep the pilot lighted, the pilot burner and or the pilot burner orifice may need to be cleaned (NG), the orifice may need to be replaced(LP), and or the air screen may need cleaning. The pilot flame should envelop approximately 10 mm (3/8") of the tip of the thermocouple. If it is too small, the pilot burner must be cleaned. To obtain a spark, the position of the Piezo igniter electrode should be approximately 3 mm (1/8") from the pilot burner tip. 3mm Correct gap between pilot burner tip and piezo electrode tip Piezo Electrode Air screen filter 10mm3/8” Fig. 8 - Characteristic Pilot Flame Thermocouple Piezo Electrode To clean the pilot burner and/ or the pilot orifice : Turn off the gas at the unit. Remove the cover of the heater. To do so, remove incandescent particle tray and unscrew the central screw located at the bottom of the front cover. Pull main cover out toward you and lift up and out. Pull the air screen off, wash it and blow any lint off (See Fig 9). The pilot orifices should also be cleaned or replaced. Do not enlarge the orifice. Do not use any wire or sharp object to clean orifices. Natural gas orifices are large enough that you can usually clean them by blowing through them. LP orifices, on the other hand, are too small to clean and should be replaced. See #3 in Trouble Shooting Section. To access the pilot orifice, remove 2 screws holding pilot assembly in place. Then loosen compression fittings to expose pilot orifice. AIR SCREEN PILOT ORIFICE Fig. 9 - Pilot burner with air screen/ pilot orifice Main Burner Flames: The main burner flames should be blue, with a more intense blue cone in the center core. Yellow flames could be a sign of wrong size gas orifices or dirty burners, or a blockage on the heat exchangers fins. 6 720 606 518 If some burners have yellow flames while others have good flames, it is likely that dust, lint or spider webs have partially clo...
Dieses Handbuch ist für folgende Modelle:Warmwasserbereiter - 125B NGS (837.44 kb)