Anleitung GE, modell BTH-120 through BTH-500

Hersteller: GE
Dateigröße: 665.37 kb
Dateiname: 569201b4-1400-4920-b95f-7420c52c882d.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


installation clearances on sides and rear, 2. installation clearance on top, 4. alcove installation clearance in front of unit • 0. clearance to combustibles, approved for combustible floors FACTORY-INSTALLED TEMPERATURE AND PRESSURE RELIEF VALVE MAXIMUM HYDROSTATIC WORKING PRESSURE: 160 PSI HANDHOLE CLEANOUT • Allows easy access to tank interior for cleaning CODES AND STANDARDS •Design-certified by UL (Underwriters Laboratories) International, according to ANSZ21.10.3-CSA4.3 standards governing storage-type water heaters • Meets ASHRAE/IESNA 90.1-1999• Design-certified by Underwriters Laboratories to NSF standard 5 for 180° F (62° C) water • Meets SCAQMD Rule 1146.2 for low-NOx emissions • ASME tank construction optional on 120 to 250 model sizes. ASME tank construction standard on 300,400 and 500 models THREE-YEAR LIMITED TANK WARRANTY • For complete warranty details, consult written warranty shipped with heater, or contact A. O. Smith INSTALLATION CONSIDERATIONS 1. Condensate Drain – This is a fully condensing water heater and should be located near a drain to permit proper disposal of condensate. 2. Vent Termination – Exhaust gases of this water heater are less than 140° F. In cold climates water vapor in flue gases will condense into a cloud of vapor where the vent exits the building. This vapor can gradually discolor exterior building surfaces. Vent termination should be located where this vapor cloud and potential discoloration are not a concern. Locating vent termination 6. or more from the wall helps vapor from being trapped along a building’s face. To avoid this problem, the vent can be terminated on the roof. Always locate vent termination above the maximum snowline, and do not locate vent termination above a walkway. 3 Air Intake – In cold climates, air intake should be located at least three feet from the vent termination of the water heater and any other appliance vents that discharge moisture-laden air (such as clothes dryers). This will help prevent freeze-over of the intake screen required to prevent foreign objects from entering the intake pipe. Air intake should be located above the maximum snowline. 4. Blockage Sensors – The water heater is equipped with sensors to shut it down if blockage of vent or air intake occurs. A light on the heater’s diagnostic panel will alert service technicians to this problem. 5. Noise – Vent terminal should be located away from bedroom windows or other areas where blower noise will be objectionable. Avoid venting into corners or confined areas, which will amplify sound. Anchoring intake or vent pipe to walls or ceilings can cause noise to be transmitted to living areas, and isolation mounts should be used where anchoring is required. 6 Optional Concentric Vent Kit - Helps to minimize unsightly wall/roof penetrations. BTH-120 - 300 vent kit p/n 9003910105 BTH-400 - 500 vent kit p/n 9006144005 Page 2 of 4 ACGSS02407 BTH-120-250 BTH-300-500 D F E G C B WATER OUTLET 1 1/2. NPT A INSTALLATION CLEARANCES Sides 0. Front 0. Rear 0. Top 1.5. To Combustibles* 0. • Approved for combustible floors GAS VALVE PIPING BTH-120 1/2. NPT BTH-150 3/4. NPT BTH-199 3/4. NPT BTH-250 3/4. NPT BTH-300 1 1/4. NPT BTH-400 1 1/4. NPT BTH-500 1 1/2. NPT MAXIMUM EQUIVALENT VENT LENGTH: BTH120 – 250 using 3. pipe: 50 ft. BTH120 – 250 using 4. pipe: 120 ft. BTH300 – 500 using 3. pipe: not applicable BTH300 – 500 using 4. pipe: 70 ft. DIMENSIONS AND SHIPPING WEIGHTS MODEL DIMENSIONS SHIP WEIGHT STD SHIP WEIGHT ASMEA B C D E F G INCHES/CM INCHES/CM INCHES/CM INCHES/CM INCHES/CM INCHES/CM INCHES/CM LBS/KG LBS/KG BTH-120 55.5/141 44.5/113 35/88.9 27.75/70.5 7.5/19.1 6.3/16 47/119.4 460Lbs/208.7Kg 490Lbs/222.2Kg BTH-150 75.5/191.8 64.5/163.8 55.5/141 27.75/70.5 7.5/19.1 6.3/16 68/172.7 555Lbs/251.7Kg 595Lbs/269.9Kg BTH-199, 250 75.5/191.8 64.5/163.8 55.5/141 27.75/70.5 7.5/19.1 6.3/16 72/182.9 555Lbs/251.7Kg 595Lbs/269.9Kg BTH-300, 400, 500 75.5/191.8 64.5/163.8 50.77/129 33.12/84.1 8/20.3 4.86/12.3 67.25/170.8 N/A 855Lbs/408.2 Kg Water connections: 1-1/2. Page 3 of 4 ACGSS02407 UP TO 96% THERMAL EFFICIENCY,DIRECT VENT RECOVERY CAPACITY U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED MODEL TYPE OF GAS INPUT Thermal Efficiency Approx. Capacity F. 30 F. 40 F. 50 F. 60 F. 70 F. 80 F. 90 F. 100 F. 110 F. 120 F. 130 F. 140 F. BTUH KW C. 17 C. 22 C. 28 C. 33 C. 39 C. 44 C. 50 C. 56 C. 61 C. 67 C. 72 C. 78 C. BTH 120 NATURAL/ PROPANE 120,000 95% 60 U.S. Gal GPH 461 345 276 230 197 173 154 138 126 115 106 99 35 227 Litres LPH 1744 1308 1046 872 747 654 581 523 476 436 402 374 BTH 150 NATURAL/ PROPANE 150,000 95% 100 U.S. Gals. GPH 576 432 345 288 247 216 192 173 157 144 133 123 44 379 Litres LPH 2179 1635 1308 1090 934 817 726 654 594 545 503 467 BTH 199 NATURAL/ PROPANE 199,900 95% 100 U.S. Gals. GPH 767 575 460 384 329 288 256 230 209 192 177 164 58...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - BTH-120 through BTH-500 (665.37 kb)
Warmwasserbereiter - BTH-120 through BTH-500 (665.37 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien