Anleitung Bock s, modell High Efficiency Condensing Gas Water Heaters
Hersteller: Bock s Dateigröße: 287.95 kb Dateiname: 8d37d6cb-c044-4930-9752-fc289c836832.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
TO VENT OUTLET G FL. TO AIR INTAKE H FL. TO T&P VALVE WATER CONN. DIA. 60 Gallon Models 57 28 1/4 42 13 53 1/2 5 52 1/2 40 1 1/2 100 Gallon Models 77 5/8 28 1/4 63 13 74 3/4 5 74.75 60 1.5 MODEL NUMBER STORAGE (GAL) RATED INPUT (BTUH) THERMAL EFF % 1ST HR DEL GAL. @ 100° F RISE RECOVERY GPH @ DEGREE RISE MAX 3” PVC, ABS & CPVC MAX 4” PVC, ABS & CPVC SHIPPING WT (LBS) 40° F 100° F 140° F 60HEC-125 60 125,000 96.0% 187 364 145 104 120 ft 170 ft 570 60HEC-150 60 150,000 93.0% 211 423 169 121 100 ft 150 ft 570 60HEC-199 60 199,999 92.0% 265 558 223 159 80 ft 130 ft 900 100HEC-150 100 150,000 99.1% 250 450 180 129 120 ft 170 ft 900 100HEC-199 100 199,999 98.5% 309 597 239 171 100 ft 150 ft 900 100HEC-250 100 250,000 97.0% 364 735 294 210 80 ft 130 ft 900 100HEC-300 100 300,000 92.0% 405 836 335 239 60 ft 110 ft 900 100-HEC-399 100 399,999 93.0% 521 1127 451 322 50 ft 100 ft 900 T&P Valve: Factory Installed Brass Drain Valve: Factory Installed Dielectric Fittings: Factory Installed Magnesium Anode Rods: Factory Installed Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi AMP Draw Range: = 1.0 to 1.8 amps and 7.0 amps for 100HEC-399; 115V A.C. required Determining required vent length 1. Determine the total length of straight vent pipe (in feet) required for both the intake and the exhaust. 2. Add 5 feet of venting for every 90° elbow. 3. Add 21/2 feet of venting for every 45° elbow. 4. Total vent length cannot exceed "Max Length" in the above chart. 5. Air intake cannot exceed exhaust by more than 30 feet in any venting situation. Do not include the 3" exhaust elbow or vent terminals in determining maximum vent length. Warning: Installation on hard surface only. Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1. Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer's directions to prevent scalding. 110 South Dickinson Street, Madison, Wisconsin 53703 Toll Free 800.794.2491 • Phone 608.257.2225• Fax 608.257.5304 80027 Rev 6/08...