Anleitung Amtrol, modell HYDROMAX HM-41Z

Hersteller: Amtrol
Dateigröße: 2.51 mb
Dateiname: 9040694_10_11_HYDROMAX_IO.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


For low-voltage wiring, strain relief at the point of exit from an enclosure is not necessary if, by wire location or support, protection is provided against accidental strain. NOTE: For models equipped with a water sensor, the water sensor should be placed flat on the floor in a low-traffic area. On a regular basis, verify that the water sensor is functioning properly by placing the orange puck in a water puddle or insert a coin between the two electrodes and listen for audible alarm. -5 Ener-G-NET™ Wiring Common wiring diagrams are shown below. Select the appropriate diagram for the application. Diagrams are popular examples only. If your application is not shown, contact Amtrol Technical Support at 401.535.1216. NOTE: Ensure the Ener-G-NET installation is within the following application and operating parameters: • Ambient temperature from 38° to 125°F • Relative humidity ranging from 20% to 90% (non-condensing). • Boiler load rating up to 15A resistive, 1/4hp inductive @ 120VAC. • Circulator load rating up to 15A, 1/4hp inductive @ 120VAC. • Space heating load rating up to 8A @ 120VAC. Oil Burner Controls BOILERMATE® CIRCULATOR HEATING CIRCULATOR ORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLET POWER BURNER PUMP PRIORITY ZR Input Terminal L1 ZR C1 C2 L2 BOILERMATE® CIRCULATOR HEATING CIRCULATOR ORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLET POWER BURNER PUMP PRIORITY 24 Volt L1 B Z W C1 C2 L2 BOILERMATE® CIRCULATOR DHW ZONE ORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLET POWER BURNER PUMP PRIORITY Multi-Zone Control: Using Post Purge L1L2 TO BOILER XX BOILERMATE® CIRCULATOR HEATING CIRCULATOR ORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLET POWER BURNER PUMP PRIORITY High Limit (B Terminal) L1 B C1 C2 L2 ORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLETPOWERBURNERPUMPPRIORITYBOILERMATE® CIRCULATORHEATINGCIRCULATORL1BB2ZWC1C2L2MillivoltBOILERMATE® CIRCULATOR OR ZONE VALVE DHW ZONE 24 OR 120VAC ORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLET POWER BURNER PUMP PRIORITY Multi-Zone Control: No Post Purge L1L2 TO BOILER XX BOILERMATE® CIRCULATORHEATINGCIRCULATORORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLETPOWERBURNERPUMPPRIORITYTriple-AquastatL1BRC1C2L2BOILERMATE® CIRCULATORHEATINGCIRCULATORORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLETPOWERBURNERPUMPPRIORITYL1BB2C1C2L2Self-GeneratingZONE VALVE END SWITCH MOTOR 24VAC ORANGEORANGEWHITEBLACKBLUEBLUEVIOLETVIOLET POWER BURNER PUMP PRIORITY 4-Wire Zone Valve TRANSFORMER L1L2 Gas Valve Controls Other Applications -6 6. Ener-G-NET™ Control Setup & Adjustment Mode Indicators Ener-G-NET features two distinct programming areas: User Modes and User Installer Settings. User Modes consist of three end-user functional Modes modes, while Installer Settings are primarily accessed upon initial setup LED to specify critical operating parameters. Ener-G-NET factory defaults Display allow traditional operation suitable for most homes. To optimize the control setup, reference the tables below. Installer Settings Temperature settings above 120° F can create a scald hazard. User Modes are used to select from three distinct operational modes. To select, press the green MODE button and press again to cycle through the three available modes. A green dot illuminates to display the current mode. User Mode Code Description Standard Traditional operation within preset temperature differential using a low and high limit. Efficiency On-Demand sensing reduces fuel consumption by limiting boiler operation during idle periods. Vacation Reduced temperature setting minimizes boiler operation during anticipaated periods of non-use. Installer Settings are used to adjust functional operating parameters. To adjust, press and hold the SET button until the Temperature setting appears. Cycle through settings by depressing the SET button and using the Ў and ^ buttons to change the settings. Setting Code Description Range Temperature Domestic hot water setpoint. Default is 120°F 90-150 Differential Domestic hot water temperature drop before call for heat. Default is 10°F. 5,10* Post-Purge Early boiler shutoff prior to hot water setpoint. Circulator runs until setpoint. Default is 0°F. 0,4,8** Priority Temporarily cancels space heat to maxmize available energy for hot water. Default is 'n'. y/n Capacity Water heater capacity; select appropriate size for proper operation. Default is 41 Gallons. 26,41,60,80,120 BTU Transfer Real-time BTU transfer estimate in 1000 BTU/Hr increments. Diagnostic readout only. 0-199MBH/Hr *Available in Standard Mode only. **Available only when Differential setting is 10. Diagnostic Error Codes display a visual indicator and sound an alarm if a fault is detected. Codes clear automatically when corrected or can be reset by interrupting power to the control for 5 seconds. To silence an alarm, depress the Ў on the keypad. Error Code Description Potential Causes*** Temp Sensor Temperature sensor (thermistor) fault. Sensor unpluggedSensor damaged Overheating Domestic hot water temperature has exceeded maximum setpoint. Err...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - HYDROMAX HM-41L (2.51 mb)
Warmwasserbereiter - HYDROMAX HM-80L (2.51 mb)
Warmwasserbereiter - HYDROMAX HM-80Z (2.51 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien