Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Desa, modell CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB

Hersteller: Desa
Dateigröße: 1.3 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


IMPORTANT:Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent. Figure 3 - Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source. WARNING: A qualified ser- vice person must install heater. Follow all local codes. 113101-01A INSTALLATION Continued NOTICE: State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes. WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue and firebox for damage. If damaged, repair flue before operating heater. WARNING: Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper. WARNING: Never install the heater • in a bedroom or bathroom unless installed as a vented appliance (Variable Manually- Controlled Models Only) (see page 12) • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater • in high traffic areas • in windy or drafty areas CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors. IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5. CHECK GAS TYPE Use only the correct gas type (natural or pro- pane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater. WARNING: This appliance is equipped for (natural or propane/ LP) gas. Field conversion is not permitted. INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall. MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size Side Wall Ceiling 18", 24" 16" 42" LOG SIZING REQUIREMENTS Log Size Minimum Firebox Size Height DepthFront Width Rear Width* 18" 24" 17" 17" 14" 14" 24" 28" 20" 21" *Measured at 14" Depth 113101-01A INSTALLATION Continued Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127listed manufactured fireplace, or certified vent-free firebox. Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 8. Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 4). Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials. B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches. * Example *Minimum 16 inches from Side Wall Figure 4 - Minimum Clearance for Combustible to Wall NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 12. Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel, page 10. If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. N...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - CGS2718NA (1.3 mb)
Warmwasserbereiter - CGS2718PA (1.3 mb)
Warmwasserbereiter - CGS3124PA (1.3 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien