Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Bradford-White Corp, modell BFM 30

Hersteller: Bradford-White Corp
Dateigröße: 1000.2 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


It is recommended that the control- thermostat be set at approximately 60°C. For reasons of security, the water heater is provided with a high limit and safety thermostats. If the high limit thermostat operates, the burner will not fire until the water has cooled sufficiently to allow the thermostat to automatically reset. The water heater will then return to the control of the temperature regulator. If the safety thermostat operates due to high temperature the ignition sequence must be repeated after resetting the control. 3.3 Turning the water heater off For short periods: 1. Turn the temperature knob fully to the left and turn the ‘I/O’-switch in the ‘O’-position. For longer periods: 1. Switch off the supply voltage; 2. Close the gas tap in the supply line; 3. Close the water supply tap; 4. If there is danger of frost, drain the water heater. 3.4. Maintenance The water heater must be checked and cleaned regularly (at least once a year) by an accredited installer, so that proper operation is guaranteed. The bar burners, the pilot burner and the control and safety valves must also be checked. 4. FAULT FINDING 4.1 Fault finding USER No or insufficient hot water. Check whether the electricity is turned on. Check whether the gas supply is turned on. Reduce the water use or increase the control thermostat. yes Does the ON/OFF switch light up? yes Does the RESETswitch light up? yes Is the water heater in operation? yes no Check ifON/OFF switch inposition 1? yes Push RESET switch up to three times no Is the water heater in operation? no Problem solved yes ON/OFF switch i. position 1. Problem solved yes Is the water heater in operation? no no Consult your installer. 4.2 Fault finding INSTALLER Check gas connection and the electricity supply make sure that they are switched on. Problem solved yes Does the ON/OFF switch light up? yes Does the RESET switch light up? no Is the water heater in operation? no Check if ON/OFF switch is in position 1? yes no Push the RESET button up to three times Put ON/OFF switch in position 1. no Is the water heater in operation? yes no Problem solved Is the water heater in operation? yes Problem solved no no See detailed fault finding 4.3 Detailed fault finding INSTALLER Check voltage present at connection 1. Check voltage present afterFILTER Check voltage present at gate 3ON/OFF switch Check voltage present at gate 11 and 12 CONTROL THERMOSTAT. yes yes yes yes no Reinstate voltage supply no no no Ensure connections correct, if yes replace FILTER Ensure connections correct, if yes replace ON/OFF switch 1. Check if controle thermostat is closed 2. Ensure connections correct. 3. If yes replace CONTROL THERMOSTAT. Ensure connections correct, if yes replace MAXIMUM THERMOSTAT Check voltage present at GATE 12 MAXIMUM THERMOSTAT? Check voltage present at GATE 1 BURNER AUTOMATION S4560D 1150? Check voltage present at GATE 8 BURNER AUTOMATION IsVENTILATING FAN in operation? Check voltage present at GATE 7, BURNER AUTOMATION Check voltage present at GATE 3 AIR PROVING SWITCH Check voltage present at GATE 1 AIR PROVING SWITCH Check voltage present at GATE 7, BURNER AUTOMATION Ensure connections correct, if yes replace BURNER AUTOMATION Replace BURNER AUTOMATION Ensure connections correct, if yes replace VENTILATING FAN Ensure connections correct Disconnect the pipe air supply by removing the elbow at the rear bottom. Measure pressure at hose H at the column. Replace BURNER AUTOMATION DISCONNECT GAS SUPPLY yes yes yes yes yes yes yes yes yesyes no no no no no no no Ensure connections correct, if yes replace MAXIMUM THERMOSTAT Check voltage present at GATE 12 MAXIMUM THERMOSTAT? Check voltage present at GATE 1 BURNER AUTOMATION S4560D 1150? Check voltage present at GATE 8 BURNER AUTOMATION IsVENTILATING FAN in operation? Check voltage present at GATE 7, BURNER AUTOMATION Check voltage present at GATE 3 AIR PROVING SWITCH Check voltage present at GATE 1 AIR PROVING SWITCH Check voltage present at GATE 7, BURNER AUTOMATION Ensure connections correct, if yes replace BURNER AUTOMATION Replace BURNER AUTOMATION Ensure connections correct, if yes replace VENTILATING FAN Ensure connections correct Disconnect the pipe air supply by removing the elbow at the rear bottom. Measure pressure at hose H at the column. Replace BURNER AUTOMATION DISCONNECT GAS SUPPLY yes yes yes yes yes yes yes yes yesyes no no no no no no no Ensure connections correct, no if yes replace BURNER AUTOMATION Ensure connections yes yes yes yes yes yes yes yes no no no no no no no Check voltage present at GATE 12 ECO Check voltage present at GATE 11 BURNER AUTOMATION Pressure H higher then 300 PA? Pressure L less then 0 PA? Check voltage present at GATE 2 BURNER AUTOMATION Does the RESET switch light up? Check voltage present at GATE 10 BURNER AUTOMATION Ensure connections correct, if yes replace ECO Ensure connections correct Measure pressure at hose H at the column Check exhaust system on blockings if the exhaust system is open, rep...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - BFM 80 (1000.2 kb)
Warmwasserbereiter - BFM 30 (1000.2 kb)
Warmwasserbereiter - BFM 50 (1000.2 kb)
Warmwasserbereiter - BFM 30 (1000.2 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien