|
Anleitung Zusammenfassung
After the automatic de-aeration programm (A xx) is finished the boiler will return to the Good reading or Technical reading. The boiler will not function directly. The automatic de-aeration program of about 17 minutes will start after one of the three program buttons is pressed. The display will show where A stands for Automatic de-aeration program Active and the number on the right indicates the actual water temperature of the boiler. Check the water pressure regularly and top up the installation when necessary. The working pressure of the installation should be between 22 and 25 PSI It can take a while before all air has disappeared from a filled installation. Especially in the first week noises can be heard which indicate the presence of air. The automatic air vent in the boiler will remove the air, which means the water pressure will reduce during this period and therefore topping up with water will be necessary to adjust the flow water temperature Turning the boiler off Holiday period: Adjust the thermostat* to the holiday period. See the user thermostat manual. The hot water facility can be switched off by means of the program button on the control panel. Re-setting the central heating system: Switch off the three program buttons , , when these are activated. Switch off the power supply. When the boiler is being drained one should take into account that a part of the heating water will remain in the boiler. When risk of frost arises one should take care that the remaining central heating water in the boiler does Holiday not freeze. * If you have a RS100 thermostat it is provided with a holiday program. The holiday period can be adjusted on the thermostat itself. The central heating and DHW supply are switched off during that period. There is also the option that only the central heatingisswitchedoff.With all of these possibilities the frost protection system is active. Operating Error, maintenance and warranty Error, maintenance and warranty iiii NOTICE NOTICE NOTICE NOTICE Operating instructions Rinnai Q-Series7 8 9 10 If a fault is detected the boiler will be blocked. This will be reflected, by an alternate display of Good, with an E of Error or a BL of Blocking and a number code. You can try to reset the boiler by pressing the Reset key once. If the problem remains please contact your installer and inform them about the fault and give them the number code. If you discover any leaks from the boiler contact your installer. We advise you to obtain a service contract with your installer for regular maintance and adjustment to keep your boiler safe and in good condition. The casing of the boiler consists of metal and plastic parts which can be cleaned with a normal non abrasive cleaning agent. Periodic cleaning of the condensate collection and disposal system must be carried out. Before putting the boiler into operation after periodic cleaning fill the condensate trap with 1.27 cups / 300 ml of water. Step 1: Condensate trap -First remove the...
Dieses Handbuch ist für folgende Modelle:Warmwasserbereiter - Q130SP (957.68 kb)
Warmwasserbereiter - Q175CN (957.68 kb)
Warmwasserbereiter - Q175CP (957.68 kb)
Warmwasserbereiter - Q175SN (957.68 kb)