Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Empire Comfort Systems, modell VFYR-24SO-1

Hersteller: Empire Comfort Systems
Dateigröße: 457.9 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Metal shipping plate covering burner marked REMOVE must be removed from top of burner and discarded. Burner will not operate if plate is left in place. Make sure you have received all parts: Check your packing list to verify that all listed parts have been received. You should have the following: • Gas log grate/burner assembly. • VFY(M,R)-16SO; 16" logs, three (3) ceramic fiber logs. • VFY(M,R)-(18, 24, 30)SO; 18", 24" and 30" logs, four (4) ceramic fiber logs. • VFY(M,R)-16RWO; 16" logs, four (4) refractory logs. • VFY(M,R)-(18, 24, 30)RWO; 18", 24" and 30" logs, five (5) refractory logs. • Two (2) masonry anchoring screws and two (2) 10 x 1/2" black sheet metal anchoring screws. • Plastic bag containing glowing embers (rock wool) for burner coverage. • Plastic bag containing lava rock. Millivolt controlled heater designed to be operated with optional devices for ON/OFF functions. • Wall switch or thermostat with wire. • Hand held remote control with ON/OFF switch or thermostat. Handle the gas log burner assembly by the grate and legs only. Do not pick the unit up by the burner. Gloves are recommended when handling ceramic fiber logs to prevent skin irritation from loose fibers. Logs are fragile Handle with care. Manual Control has five (5) positions Off – All gas to set is completely off at the valve. Pilot – Valve position to light/maintain the standing pilot. Low – Min. gas rate - pleasing yellow flames - glowing embers. Medium – Middle gas rate - pleasing yellow flames - glowing embers. High – Max. gas rate - pleasing yellow flames - glowing embers. Millivolt Control has four (4) positions Off – All gas to set is completely off at the valve. Pilot – Valve position to light/maintain the standing pilot. Low – Min. gas rate - pleasing yellow flames - glowing embers. High – Max. gas rate - pleasing yellow flames - glowing embers. Ignition – Piezo Ignitor allows lighting of the pilot without matches. Pilot – All gas log heaters are designed with safety pilot systems that will shut down when the level of oxygen available in the room is low. The pilot will only relight when adequate fresh air is available. Thermal – All millivolt logs are fitted with a thermo Generator generator to provide millivolt power to activate switches, remote controls or thermostats. Qualified Installing Agency Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction. State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.* *Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10018. High Altitudes: For altitudes/elevation above 2,000 feet ratings should be reduced at the rate of 4 percent for each 1,000 feet above sea level. Contact the manufacturer. 12409-2-0403 Page 6 WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather. The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized p...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - VFYM-24RWO-2 (457.9 kb)
Warmwasserbereiter - VFYM-16RWO-2 (457.9 kb)
Warmwasserbereiter - VFYM-16SO-2 (457.9 kb)
Warmwasserbereiter - VFYM-18RWO-2 (457.9 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien