Anleitung Crown, modell GB/GW-750

Hersteller: Crown
Dateigröße: 550.11 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3. The display will illustrate Circ. Enter this mode by pressing the ENTER/RESET push-button. 4. The display will now illustrate the current post circulate time. Press the ADJUST push-button to select the desired post circulate time (45, 90, 180, On). 5. When you have selected the desired post circulate time mode, press the ENTER/RESET push-button once, this enters the selected post circulate time into controller memory. 6. The display will automatically resort to illustrating the outlet temperature. Display Current Mode In this mode, the Display Board will illustrate the current functional step in the appliance operational sequence. For example, if the appliance is performing Ignitor Warm-up, the display will illustrate IGnt. To enter into this mode, perform the following steps: 1. Press the SELECT push-button on the display board until the LED display reads OPt (Options). 2. To enter into the options mode, press the ENTER/RESET push- button. 3. The display will illustrate Circ. Press the SELECT push-button until the display illustrates StEP. Enter this mode by pressing the ENTER/RESET push-button. 4. The display will illustrate the current appliance operating step. 5. The display will automatically resort to illustrating the outlet temperature. To keep the display in the Display Step Mode, press ENTER/RESET twice in step 3. Display Message Appliance Mode IdLe Idle state NoSn Wait for No Sensor Inputs CrSn Wait for Circulate Sense Circ Circulate Pump is ON PrSn Wait for Blower Pressure Sense PreP Pre-Purge state IGnt Ignitor Warm-up rEdn Turn ON redundant Gas Valve relay IAct Turn ON Gas Valves StAb Turn OFF Ignitor and wait for Flame Sense Stabilization HEAt Heat Mode PoPC Post Purge and Post Circu late Po C Post Circulate Display Total Cycle Count The Main Control Board counts the number of cycles the appliance has operated. In the Main Control Board, a cycle is counted every time the gas valve is energized. To access this number, perform the following procedure: 1. Press the SELECT push-button on the display board until the LED display reads OPt (Options). 2. To enter into the options mode, press the ENTER/RESET push- button. 3. The display will illustrate Circ. Press the SELECT push-button until the display illustrates Count. Enter this mode by pressing the ENTER/RESET push-button. 4. The display will now illustrate the current number of cycles the appliance has cycled through. 5. The display will automatically resort to illustrating the outlet temperature. TANK PROBE INSTALLATION PROCEDURE A tank probe is supplied with each hot water supply boiler. When installed on a tank, the inlet water temperature on the Dia-Scan II will default to the tank temperature. See figures 2 and 3 to add the tank jumper to the control board so that the tank probe is active. A tank probe is NOT supplied with the hydronic heating boilers (GB's). Therefore, a loop or operating thermostat must be provided. This field-supplied operating thermostat should be wired to...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - GB/GW-200 (550.11 kb)
Warmwasserbereiter - GB/GW-200 (550.11 kb)
Warmwasserbereiter - GB/GW-400 (550.11 kb)
Warmwasserbereiter - GB/GW-200 (550.11 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien