Solid State water level control for automatic refill WATER INLET (1/4 " FLARE) 3.4 16.0 SIDE ACCESS DOOR (SLIDES UP) OVERFLOW 4.0 THERMOMETER "B" 14.0 5.0 CAUTION HOT SURFACES ME10-GN NP87A TEMPERATURE CONTROL NOTE: UNIT IS SUPPLIED WITH A GROUNDED 120V-15A LINE CORD AND PLUG (NEMA 5-15P). PROPANE GAS BTU/ HR @ 10" W.C. 12,000 NATURAL GAS BTU/ HR @ 3.5" W.C. GAS SPECIFICATIONS 12,000 MODEL NO. ME10-GN ME15-GN GENERAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS "A" POWER SWITCH TEMPERATURE CONTROL GAS FLUE LINE CORD WITH PLUG GAS INLET (3/8 " NPT) 1 FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. THIS INSTALLATION MUST CONFORM WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.1 (LATEST EDITION). WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. SAFETY PRECAUTIONS FOR YOUR SAFETY, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE FOLLOWED AND ENFORCED. IF YOU SMELL GAS: • OPEN WINDOWS • DON’T TOUCH ELECTRICAL SWITCHES • EXTINGUISH OPEN FLAMES • IMMEDIATELY CALL YOUR GAS SUPPLIER 1. Instructions must be posted in a prominent location and all safety precautions taken in the event the user smells gas. Obtain this information from your local gas supplier. 2. LIGHTING: Follow the instruction on page 2 and label attached to right side of the water boiler. 3. Do not place anything over the flue opening. 4. Do not place combustibles or non-combustible materials in the proximity of coffee urn as this could cause fires or obstruct air flow to the main burners. 5. This installation must conform with local codes, or in absence of local codes with the National Fuel Gas Code ANSI Z223.1, latest edition. 6. Provide adequate air supply and ventilation. 7. Provide adequate clearance for air openings into the combustion chamber. 8. Provide clearance for servicing and proper operation. Minimum clearance from combustible construction 8” from back and 6” from side. 9. Boiler must be disconnected from gas supply during any pressure testing of pipelines in excess of . psig, and isolated (by turning off gas shut-off valve) during any testing less than . psig. 10. Retain this manual for future reference. UNPACKING INSTRUCTION: Carefully unpack the water boiler and inspect immediately for shipping damages. Your automatic water boiler was shipped in a carton designed to give maximum protection in normal handling. It was thoroughly inspected before leaving the factory and the carrier accepted and signed for it. File any claims for shipping damage or irregularities with the carrier. 2 ASSEMBLY: The four legs and vent cap drain are packed separately with the water boiler. Install legs by tilting the water boiler on its side and screwing the legs into the leg supports until hand tight. Carefully right the unit and install in its permanent location, being sure to leave at least 6” on the right side of the water boiler for access to the control box. Level the unit by adjusting the bottom pad of the legs. Place the vent cap into the recess in the top of the unit. Mount the faucet assembly onto the shank in upright position. INSTALLATION AND OPERATING INSTRUCTION: PRE-INSTALLATION INSTRUCTIONS: The installation of your water boiler must be made by a licensed plumber and the installation must conform with State and Local Codes or in absence of Local Codes, with the National Fuel Gas Code ANSI Z223.1 a latest version. AIR SUPPLY AND VENTILATION: Adequate ventilation and air supply must be provided in order for the water boiler to operate properly and efficiently. The area in front of and above the unit must be clear to avoid any obstruction of flow of combustion and ventilation air. DO NOT under any circumstances, connect the water boiler flue directly to a building exhaust system or place the flue outlet directly into the plenum of the exhaust hood as it will adversely affect the gas combustion of the water boiler. CLEARANCES: Your water boiler is design certified to use on combustible floors. The side and back clearances for combustible constructions are as follows: 6 inches from side and 8 inches from back. The water boiler must be installed with 4 inch high legs provided. GAS CONNECTION: Before connecting the water boiler to the gas line Examine the gas specification label attached to the right side panel to be certain that the type of gas for which the unit is equipped is the same as the gas supply. A 3/8 NPT gas connection is needed to connect the unit to the gas line. An accessible manual shut-off valve must be installed in the gas supply line in case of an emergency. The gas supply pipe must be sized to accommodate all the gas fired equipment that may be connected to it. Check with your local Gas Company as to proper pipe size. Sealant on all pipe joints must be resistive to propane ...
Dieses Handbuch ist für folgende Modelle:Warmwasserbereiter - ME15-GN (1.21 mb)