|
Anleitung Zusammenfassung
Devices Camera PTZ Term Symbol Meaning No. Number of camera Product PTZ camera type as per specified list ID Unique ID of PTZ camera Port Interface type of PTZ cameras Setup… Settings as specified by PTZ camera manufacturer: Baud Rate Data Bit Stop Bit Parity DLR -XXN/XX 5 Setup menu, continued Devices – Alarm-Out On the “Alarm-Out” menu the alarm outputs are configured. . “Settings” tab: The alarm outputs are configured. . “Schedule” tab: Time slots are defined in which the alarm outputs respond in specific ways. Setup Menu... Devices Alarm-Out Settings Term Symbol Meaning No. Number of alarm output Title Name of alarm output Type Contact method of alarm output: NO Normally Open NC Normally Closed Dwell Duration of alarm signal Setup Menu... Devices Alarm-Out Schedule Term Symbol Meaning No. Number of schedule entry Day Day of the week Range Time range at 15-minute intervals Mode Response in defined period: On Continuous alarm Event Alarm in response to event Off No alarm Channels Enable Alarm outputs internal beep by DVR . . 6 DLR -XXN/XX Setup menu, continued Devices – Display On the “Display” menu the mode of on-screen display is configured. . “OSD” tab: Specify what additional information is displayed on-screen. . “Main Monitor” tab: Specify how the camera images are displayed on the main monitor. . “Spot Monitor” tab: Specify which cameras are displayed on the spot monitors. Setup Menu... Devices Display OSD Term Symbol Displayed symbol Meaning Progress Activates display of: Zoom Visible when Zoom mode enabled Network Visible when DVR operating in a network Freeze & Sequence Freeze Visible when Sequence mode enabled . . Screen Group 1/4 Displays number of groups, and their ID numbers Free Space Visible when Recycle mode enabled Remaining hard disk capacity, if Recycle mode not selected . . Date -Date Time -Time User Name -Display of user name Camera Activates display of: No. -Display of camera number Title -Display of camera title Record Display of Record symbols PTZ Visible when PTZ camera is displayed Text-In -Display of character string Display Dwell -Text In Dwell Time Transparency -Transparency of menu screens OSD Margin... -Distance of displayed symbols from screen margin DLR -XXN/XX 7 Setup menu, continued Setup Menu... Devices Display Main Monitor Term Symbol Meaning Mode Modes of sequences in multiple playback: Full Sequence All cameras are switched through sequentially. Cameo Only the image at the bottom right is switched through; cameras in „Covert“ mode are not displayed to users without „Covert“ access. Interval Time interval between picture refresh Event Monitoring On Displays image of relevant camera in full-screen mode when an event occurs Setup Menu... Devices Display Spot Monitor Term Symbol Meaning No. Number of spot monitor output Channels Cameras Display time of recordings from cameras on spot monitor . . Devices – Remote Control On the “Remote Control” menu the remote control function is configured. Setup Menu... Devices Remote Control Term Symbol Meaning Port Interface type of remote control Setup… Setup as specified by manufacturer: Baud Rate Data Bit Stop Bit Parity Remote Control Product Remote control type as per specified list 8 DLR -XXN/XX Setup menu, continued Record – Record On the “Record” menu the basic settings for recordings and their quality are made. Setup Menu... Record Record Term Symbol Meaning Recycle Enables automatic overwriting of the oldest recordings when the hard disk is full Note: If not enabled, recording ends when the hard disk is full. Resolution Quality of recorded images Standard CIF High 2CIF Event Record Dwell Duration of recording when an event occurs Auto Deletion Specify time after which automatically deleted Use Panic Recording Enables the panic recording function Panic Recording Duration Duration of panic recording No Limit End panic recording by pressing PANIC button xx min. Panic recording ends after preset time or by pressing PANIC button ips Number of recorded images per second in panic recording Quality Picture quality of the recorded images in panic recording DLR -XXN/XX 9 Setup menu, continued Record – Schedule On the “Schedule” menu the schedule for recording is defined. Setup Menu... Record Schedule Term Symbol Meaning Schedule On Enables schedule entries Note: A recording is made only if schedule entries are enabled. Otherwise only panic recording is possible. No. Number of schedule entry Day Day of the week Range Time range at 15-minute intervals Mode Response: No Record - Time Always record in the defined time slot in the quality set for “Time” mode Event Record only in case of event in the defined time slot in the quality set for „Event“ mode Time & Event Always record in the defined time slot in the quality set for “Time” mode, also in case of event in the defined time slot in the quality set for “Event” mode Channels Assignment of cameras to schedule Settings Picture data settings in Time and Event modes: ips Number of recorded...
Dieses Handbuch ist für folgende Modelle:Überwachungstechnik - DLR3-08N/160CDV (456.07 kb)
Überwachungstechnik - DLR3-08N/410CDV (456.07 kb)
Überwachungstechnik - DLR3-08N/660CDV (456.07 kb)
Überwachungstechnik - DLR3-16N/160CDV (456.07 kb)