Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Chamberlain, modell SL-5512

Hersteller: Chamberlain
Dateigröße: 258.52 kb
Dateiname: 595-5575-06.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Automatically turns lighting off. • Dual Brite™ Timer. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). This package includes: Plastic Hanger Rubber Plug 6 MountingCover Screws (3 sizes) 3 Wire Connectors Mounting Bolt Light Control Mounting Strap Gasket 2 Halogen Bulbs Light Shield Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualified electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. PlateSensor OPERATION Mode: On-Time: Works: Day Night Test 5 Sec x x Auto 1, 5, 20 min. x Manual Until Dawn* x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. TEST TEST 1 5 20ON-TIMEOff 3 6 Dusk to DawnDUAL BRITE™Put ON-TIME switch on the sensor bottom to TEST and the Dual Brite™ switch OFF. AUTO ON-TIMETEST 1 5 20Put the ON-TIME switch in the 1, 5, or 20 minute position. MANUAL MODE ... back on. 1 Second OFF then... Mode Switching SummaryManual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second thenbackontotogglebetweenAUTO and MANUAL MODE. ManualmodeworksonlywiththeON-TIMEswitchinthe1,5,or20position. Move ON-TIME Switch to 1, 5 or 20 minutes Flip light switch off for one second then back on* * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. Dual Brite™ TIMER Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn).If motion is sensed, the light turns on full bright for the ON-TIME (1,5 or 20 minutes) then returns to dim mode. TEST AUTO MANUAL MODE © 2005 DESA Specialty Products™ 595-5575-06 INSTALLATION WIRE THE LIGHT CONTROL. For easy installation, select an existing light operated by a wall switch for replacement. For best performance, mount the fixture about 8 ft.(2.4 m) above the ground. CAUTION: Keep the sensor at least 1" (2.5 cm) away from the lamps. CAUTION: To Avoid Fire Or Burn Hazards: • Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures. • Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet. (1 m). • Use only T3, 150W (max.) tungsten halogen 120 VAC lamps. For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing from the Light Shield and stick on as shown below. For eave mount only: . Swing the sensor head towards the clamp screw joint. If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint.Tighten the clamp screw when done. . Then rotate the sensor head clockwise 180° so the controls face down. ControlsControlsControlsClamp ScrewLight Shield Opening BULB INSTALLATION. NOTE: Lamps are included, but you will need to install them NOTE: When re-lamping, turn power off and let the fixture cool. . Open glass covers. To remove the old bulb push the bulb towards the right (with fixture as shown) until the left side of the bulb is clear of the left socket. . To install a bulb, push the bulb into the right socket so the bulb fits completely into the left socket. . Check that the bulb is seated properly. . Close the glass covers. . Turn power off at the fuse or circuit breaker. . Remove the existing light fixture. . Install mounting strap to junction box using screws appropriate for your junction box. . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. . Thread all fixture wires through the large holes in the gasket as shown. . Connect the junction box wires to the light fixture wires as shown. Twist together and secure with wire connectors. Black to BlackWhite to WhiteGasketConnectanyfixturegroundwire(s)andthecoverplate ground screw to the junction box ground wire. Rubber PlugMounting Bolt MOUNT THE LIGHT CONTROL. . Place the Mounting Bolt through the front of the junction box cover. Push the small gasket hole over the Mounting Screw. . Make sure the wire connectors and wires are inside the junction box. Align the Mounting Screw with the center hole in the Mounting Strap.Secure the fixture to the Mounting Strap. Push the Rubber Plug over the mounting screw. Keeplampsatleast1" (2.5 cm) from the sensor. . Push the Rubber Plug firmly into place. . If not installed on a weatherproof box, caulk the wall plate and mounting surface with silicone . Adjust the lamp holders by loosening the lock nuts but do not rot...

Dieses Handbuch ist für folgende Modelle:
Überwachungstechnik - SL-5512 (258.52 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien