Anleitung Zusammenfassung


. Replace the rubber cover to protect controls. Aim Sensor Out for Long Coverage Expected Coverage The sensor is less sensitive to motion directly When mounted 8 feet (2.4 m) from the ground, towards it, most sensitive to motion across its field you may expect the range shown below. If of view. mounted much higher the sensor may miss objects near the ground. If mounted much lower the 70 ft. 100 ft. Least Sensitive Most Sensitive (21 m) (30,5 m) (Boosted) Sensor Maximum Range sensor range may be reduced. 8 ft. (2.4 m) Motion Motion -10-595-5631-07 If the wide angle (270°) coverage is too wide for your application, you may need to install the lens shield to reduce the coverage angle. . Decide which side of the lens you want to cover. . Curve the shield as shown. Slide the shield down, under the two metal ribs of the case. Make sure the shield slides all the way down so the entire shield will lay directly against the lens. . Slip the small protrusion behind the vertical metal rib to hold the top of the shield in place. Slip behind vertical rib Lens shield Metal ribs Maximum Coverage Angle 270° Approx. area blocked by the lens shield (if used) If the sensor is not kept level you may experience an apparent decrease in range because objects may pass under the detection zone without being detected. 595-5631-07 -11 Operation Mode: On-Time: Works: Day Night Test 5 Sec x x Auto 1, 5 or 20 min. x Manual Until Dawn* x MANUAL MODE Manual Mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one * resets to Auto Mode at dawn. second then back on to toggle 1 Second OFF then... RANGE BOOST between AUTO and MANUAL Turn Range Boost on for addi- tional coverage only if needed. Off On Range Boost MODE. Manual Mode works with the ON-TIME switch in the 1, 5, or 20 minute position. ... back on. TEST TEST 1 5 20 ON TIMEPut the ON-TIME switch on the sensor bottom in TEST and the Range Boost switch to Off. AUTO ON TIME TEST 1 5 20 Move ON-TIME Switch to 1, 5 or 20 minutes Flip light switch off for one second then back on* * If you get confused while switching modes, MANUAL MODE AUTO TEST Put the ON-TIME switch in the 1, 5 or 20 minute position. turn the power off for one minute, then back on. After the calibration time, the control will be in the AUTO mode. -12-595-5631-07 Troubleshooting Guide SYMPTOM POSSIBLE CAUSE Lights will 1. Light switch is turned off. not come 2. Flood light is loose or burned out. on. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turnoff is in effect. (Recheck after dark). 5. Incorrect circuit wiring, if this is a new installation. 6. Re-aim the sensor to cover desired area. Lights come on in daylight. 1. Control may be installed in a relatively dark location. 2. Control is in Test. (Set control switch to an ON-TIME position). Lights come on for no apparent reason. 1. Control may be sensing small animals or automobile traffic. (Reaim sensor or use lens shield). 2. Sensitivity is set too high.(Reduce sensitivity. Turn Range Boost off). SYMPTOM POSSIBLE CAUSE Lights stay on continuously. 1. A lamp is positioned too close to the sensor or pointed at objects that causes the sensor to trigger. (Aim the lamp away from the sensor or objects). 2. Control is pointed at a heat source like an air vent, dryer vent, or brightly- painted heat-reflective surface.(Reaim sensor. Turn Boost off). Lights flash on and off. 1. Heat or light from the lamps may be turning the Light Control on and off. (Aim lamps away from the sensor. Turn Boost off). 2. Reflected heat from other objects are triggering the sensor. (Re-aim sensor. Turn Boost off). 3. Control is warming up. (Flashing is normal under these conditions. Wait 1 minute for sensor to warm up). 4. Control is in Test.(Set control switch to an ON-TIME position). Technical Service (Do Not Send Products) If you experience a problem, follow this guide. You may also want to visit our Web site at:If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™ P.O. Box 90004, Bowling Green, KY 42102-9004 * If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase. No Service Parts Available for this Product 595-5631-07 -13 Lifetime Warranty This is a "Limited Warranty" which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For as long as you (the original purchaser) own this JourneyMan® product, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase. Not Covered -Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items are not covered by this warranty. Unauthor...

Dieses Handbuch ist für folgende Modelle:
Überwachungstechnik - JOURNEYMAN HD-9240 (826.6 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien