Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Health O Meter, modell PROPLUS 2000KL

Hersteller: Health O Meter
Dateigröße: 646.46 kb
Dateiname: ProductAdditionalInfoItemOriginal1662.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Please read this manual carefully and keep it handy for ready reference. TABLE OF CONTENTS CAUTION AND WARNING....................................................................................................2 SPECIFICATIONS.................................................................................................................3 ASSEMBLY INSTRUCTION..................................................................................................4 SET UP..................................................................................................................................10 OPERATION INSTRUCTIONS..............................................................................................11 MAINTENANCE.....................................................................................................................23 TROUBLESHOOTING...........................................................................................................24 CALIBRATION PATH............................................................................................................25 EXPLODED VIEW OF SCALE ..............................................................................................25 PARTS LIST..........................................................................................................................27 WARRANTY ..........................................................................................................................28 1 CAUTION AND WARNING To prevent injury and damage to your scale, please follow these instructions very carefully. • To ensure proper operation of the ProPlus® Stretcher Scale, this operation manual should be reviewed carefully before operation. Keep this manual available for future reference, and also for use in the orientation of new personnel. • If the scale becomes damaged, it should not be operated until properly serviced. All repairs should only be performed by authorized Healthometer® Professional service personnel. • This scale is designed for static weighing of patients only. No scale should be used for patient transfer. Healthometer® Professional / Pelstar LLC assumes no responsibility for patient injury or scale damage should this caution be ignored. • Do not leave patients unattended while on the scale. • For accurate weighing the scale must be placed on a flat and stable surface with the locking screw locked properly and the weighing mechanism not touching the floor. • For accurate weighing, verify proper operation according to the procedure described in this manual before each use. • Do not use in the presence of flammable materials. • Operating at other voltages and frequencies than specified could damage the equipment. • If the “LOW BAT” indicator activates, for accurate weighing, replace the batteries or connect the scale to an AC power source as soon as possible. • Failure to comply with the following will void scale warranty: o Do not gas sterilize or autoclave the scale. o Do not place liquids on top of the scale display console. o Do not exceed recommended weigh limit of 400 lb/181kg for this scale. o This scale contains delicate sensors. Do not bang into doors, elevators, etc., as damage may result. 2 SPECIFICATIONS GENERAL Health o meter’s ProPlus® Stretcher Scale Model 2000KL uses highly sophisticated microprocessor technology. This scale is designed to provide accurate, reliable and repeatable weight measurements and features that make the weighing process simple, fast and convenient. The scale is set up to use motion-sensing weighing technology, to determine the actual weight of a moving patient. The scale may be changed to measure live weight; see page 19 for instructions on changing the scale setting. The weight can be displayed in pounds (decimals, fractions of a lb or lb/oz) or in kilograms. The scale features a folding stretcher for easy mobility and a display assembly stand. The unit can be operated using its AC adapter or by 6-D cell batteries (not included). SCALE SPECIFICATIONS Capacity and Resolution 400 Lb x 0.2 Lb / . lb / 4 oz (181 Kg x 0.1 Kg) Power Requirements Adapter 120VAC - 6VDC - 60Hz or 6 x D size batteries Environmental Operating temperatures: 50°F to 95°F (10°C to 35°C) Storage temperatures: 30°F to 125°F (0°C to 50°C) Humidity: 85% Stretcher Dimensions Closed: Length: 70 .” (180 cm) Width: 6” (15 cm) Weight: 16.5 Lb (7.5 Kg) Fully extended: Length: 70 .” (180 cm) Width: 29.” (75 cm) 3 ASSEMBLY INSTRUCTIONS Before Assembly The Model 2000KL ProPlus® Stretcher Scale is shipped disassembled in two (2) separate cartons. Carefully inspect all cartons for shipping damage before unpacking. If damage is found, contact your shipper or Healthometer Professional immediately. Claims must be filed with the shipper as soon as possible after receipt of the damaged package. Remove each assembly from the carton and unwrap packing material carefully to prevent scratching the unit’s parts. It is recommended that two...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien