Anleitung Rangemaster, modell LEIHDS120SC
Hersteller: Rangemaster Dateigröße: 251.3 kb Dateiname: 0d76f760-d50f-4a3f-946a-5335da8929a4.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
THIS APPLIANCE CAN BE A POSSIBLE FIRE HAZARD IF THE GREASE FILTERS ARE NOT CLEANED AND THE CHARCOAL FILTERS REPLACED AS RECOMMENDED. Replacement charcoal filters may be purchased by returning the enclosed order form, or by telephoning 01803 296155 if you wish to pay by credit card. 6 MAINTENANCE AND CLEANING LIGHTING The canopy is fitted with three 20W halogen spotlamps. If one of the spotlamps fails to function check that the two pins are correctly inserted into the lamp holder. To replace a spotlamp remove the two screws, which secure the lens retaining ring and glass lens as illustrated. Take care to ensure the lens and retaining ring are supported while removing the screws. Extract the spotlamp from the lamp holder by pulling gently. Replacement spotlamps are specified 230V 20W. When replacing the spotlamps, make sure that the two pins are correctly inserted in the lamp holder, and then replace the glass lens and retaining ring. CLEANING We recommend the chimney hood is cleaned using a damp cloth wrung out in warm soapy water using a mild liquid household cleaner. Never use excessive amounts of water when cleaning, in particular around the control buttons. Never use thinners or products containing alcohol, as they will damage the painted or bright metal finish. Never use abrasive cleaning materials, or scouring pads in particular when cleaning painted or bright metal finish. 7 INSTALLATION INSTRUCTIONS It is dangerous to alter the specifications or attempt to modify this chimney hood in any way. TECHNICAL INFORMATION DIMENSIONS CANOPY: Height 60mm Width 1198mm Depth 490mm CHIMNEY: Height - Upper Chimney 215mm Lower Chimney 740mm Width 300mm Depth 260mm ELECTRICAL SUPPLY VOLTAGE: ~50Hz 230V POWER CONSUMPTION: 200W FAN: 140W SPOTLAMPS: 3x20W 60W PERFORMANCE SPEEDS 3 CAPACITY m3/h* 550 CAPACIITY m3/h** 690 PRESSURE PA 340 INPUT W 200 NOISE LEVEL dBA*** 67 *IEC 61591 method for cooker hoods in evacuation mode - ** IEC 61591 method with free delivery - ***IEC 60704-2-13 method Note: CE Marking certifies that this appliance complies with the requirements laid down in EEC directive 89:336 (Electromagnetic compatibility) and subsequent modifications and Low Voltage directive 72/23/E. 8 ELECTRICAL CONNECTION THIS APPLIANCE MUST BE EARTHED ELECTRICAL REQUIREMENTS Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC). ELECTRICAL CONNECTION Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. This appliance is fitted with a 3 core mains cable and must be permanently connected to the electricity supply via a double-pole switch having 3mm minimum contact gap on each pole. A Switched Fuse Connection Unit to BS.1363 Part 4, fitted with a 3 Amp fuse, is a recommended mains supply connection accessory to ensure compliance with the Safety Requirements applicable to fixed wiring instructions. This appliance conforms to BS.800:1988 and EEC Directive No. 78 308 regarding suppression of radio and television interference. 9 INSTALLING THE CHIMNEY HOOD COMPONENTS The chimney hood comprises of the following: No 1 150x120mm ducting spigot (A) No 1 120x125mm ducting flange (B) No 1 Canopy (C) No 2 Recirculation grilles (G) No 1 Lower chimney stack (I) No 1 Recirculation ducting (P) No 2 Recirculation extension ducts (P1) No 1 Recirculation spigot (R) No 1 Upper chimney stack (S) No 1 Valve (V) optional No 2 Chimney fixing brackets (2) Please ensure when the appliance is fitted it is easily accessible to an engineer in the event of a breakdown. All installations must comply with local authorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this chimney hood. INSTALLATION REQUIREMENTS Before installation check the wall to which the hood is to be fitted for electric cables, gas and water pipes. This chimney hood is designed to be fixed to any vertical surface over a cooking area, and can be used in the extraction (ducted to the outside) or recirculation mode. The installation work must be undertaken by a qualified and competent person. Leisure Consumer Products disclaims any responsibility for damage due to incorrect installation of the chimney hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation. 10 INSTALLING THE CHIMNEY HOOD CLEARANCE HEIGHTS The chimney hood is designed to be fitted over a cooking appliance. A minimum clearance height of 650mm (25.ins) is required when installed above a built-in electric hob, or 700mm (27.ins) when installed above a built-in gas hob. When installed between adjoining wall cabinets, the wall cabinets must not ...