|
Anleitung Zusammenfassung
‡ For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation. *The blower assembly part number is 5304444802 — shipped in separate box. NOTE: Always consult local and national electric codes. Refer to Product Installation Guide for detailed installation instructions on the web at electroluxicon.com. Specifications subject to change. Infinite-Speed Control The ultraquiet blower allows you to dial in the precise airflow needed. Removable, Easy-Clean Filters Filters are easy to remove and clean in your dishwasher to restore to like-new condition. 10"-High Intake When activated, the downdraft vent rises 10" to capture even the most stubborn cooking odors. Slim Style Designed to work in perfect harmony with your approved gas or electric cooktop. electroluxicon.com 30" Downdraft Vent Specifications • Voltage Rating –120V/ 60Hz/15 Amps • Connected Load (kW Rating) @120 Volts = 1.0kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @120 Volts = 8.0 Amps • Do not use same circuit as cooktop. • Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale. • 1,600 CFM remote exhaust blower (PN# 5304444802) included with vent – shipped in separate box. • Vent must be installed in vertical orientation only. • Vent unit outside of building only. • Exhaust Duct Required – 3-1/4"x10" (3-1/4"x10" to round transition duct will be needed) • Do not use flexible duct. Round duct instead of rectangular duct recommended, especially when elbows are required. • When multiple elbows are necessary, ensure a minimum of 24" of straight duct between any two elbows. • Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold. • For most efficient airflow exhaust, use a straight run or as few elbows as possible. • Cold weather installations should have additional backdraft damper installed. • Installing a Downdraft Vent in combination with any gas cooking surface will affect optimum burner efficiency. • Downdraft Vents can NOT be used in combination with any cooktop backsplash. • Downdraft Vent model E30DD75ESS is approved to be used in combination with Electrolux ICON® Drop-In Cooktop models E30EC65ESS, E30EC70FSS, E30IC75FSS, E30IC80ISS, E30GC64ESS, E30GC70FSS; and Electrolux ICON® Slide-In Cooktop model E30GC74GPS. (For detailed countertop preparation, refer to Drop-In and Slide-In Cooktop/Downdraft Vent Countertop Preparation pages on web.) • Proper combination installation of Electrolux ICON® Downdraft Vent model E30DD75ESS and approved 30" Gas Slide-In Cooktop will require cooktop power cord to be relocated to underside of unit. (For details, refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation Instructions on web.) Note: For planning purposes only. Refe...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - ICON E30DD75ESS (800.47 kb)
Ventilatoren - ICON E30DD75ESS (800.47 kb)
Ventilatoren - ICON E30DD75ESS (800.47 kb)
Ventilatoren - ICON E30DD75ESS (800.47 kb)