Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Desa, modell 44 kW (150

Hersteller: Desa
Dateigröße: 1.09 mb
Dateiname:
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause the flame-out control to shut down heater. Foreign matter may also require you to clean fuel system often. WARNING Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol or other highly flammable fuels. 6 099623 VENTILATION OPERATION WARNING Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater. Provide a fresh air opening of at least 2800 square cm (three square feet) for each 29,3 kW (100,000 Btu/Hr) rating. Provide extra fresh air if more heaters are being used. Example: A 44 kW (150,000 Btu/Hr) heater requires one of the following: • a 4,88 m (16 foot) wide two-car garage door raised 8,59 cm (3.38 inches) • a 2,75 m (9 foot) wide single-car garage door raised 15,24 cm (6 inches) • two, 76,20 cm (thirty-inch) wide windows raised 28 cm (11 inches) WARNING Review and understand the warnings in the Safety Information Section. They are needed to safely operate this heater. Follow all local codes when using this heater. To Start Heater 1. Follow all ventilation and safety information. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. Plug power cord of heater into standard 230 volt/50 hertz, grounded (earthed) outlet. Use an extension cord if needed. Use only a grounded (earthed) extension cord. Extension Cord Wire Size Requirements Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm2) conductor 101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm2) conductor Heater will start when power cord is plugged into outlet. If not, push in flameout control reset button (see Figures 6 thru 8). Flame-Out Control Reset Button Figure 6 - Flame-Out Control Reset Button, 8,8/20,5 kW (30/70,000 Btu/Hr) Models Continued Flame-Out Control Reset Button Figure 7 - Flame-Out Control Reset Button, 26,4 kW (90,000 Btu/Hr) Model 7 OPERATION Continued STORING, TRANSPORTING, OR SHIPPING PREVENTATIVE MAINTENANCE SCHEDULE Flame-Out Control Reset Button (Fan Guard Removed) Figure 8 - Flame-Out Control Reset Button, 44 kW (150,000 Btu/Hr) Model To Stop Heater 1. Unplug power cord from outlet. To Restart Heater 1. Wait 2 minutes after stopping heater. 2. Repeat steps under To Start Heater, page 7. Note:If shipping, transport companies require fuel tanks to be empty. 1. Drain fuel tank. Note:Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed. 2. Replace drain plug if provided. 3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use. 4. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil. 5. If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes. IMPORTANT:Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater. WARNING Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Item How Often How To Fuel tank Flush every 150-200 hours See Storing, Transporting, or of operation or as needed. Shipping, above. Air output and Replace every 500 hours of See Air Output, Air Intake, lint filters operation or once a year. and Lint Filters, page 14. Air intake Wash and dry with soap and See Air Output, Air Intake, filter water every 500 hours of and Lint Filters, page 14. operation or as needed. Fuel filter Clean twice a heating season See Fuel Filter, pages 10 or as needed. and 11. Continued 8 Continued TROUBLESHOOTING Item Spark plug How Often Clean and regap every 600 hours operation or replace as needed. How To See Spark Plug, pages 12 and 13. Fan blades Clean every season or as needed. See Fan, page 19. Motor Not required/permanently lubricated WARNING Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. OBSERVED FAULT POSSIBLE CAUSE REMEDY Heater ignites, but Wrong pump pressure See Pump Pressure flame-out control Adjustment, page 14. shuts off heater after Dirty air output, air intake,See Air Output, Air Intake a short period of and lint filters and Lint Filters, page 14. time. Dirty fuel filter See Fuel Filter, pages 10 and 11. Dirt in nozzle See Nozzle, pages 15 thru 17. Dirty photocell lens Clean photocell lens. Bad flame-out control Replace flame-out control. Heater will not Wrong pump pressure See Pump Pressure ignite, but motor runs Adjustment, page 14. for a short period of Carbon deposits on spark See Spark Plug, pages 12 ti...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - 20 (1.09 mb)
Ventilatoren - 26 (1.09 mb)
Ventilatoren - 000 Btu/Hr) (1.09 mb)
Ventilatoren - 000) (1.09 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien