|
Anleitung Zusammenfassung
It also counteracts the tendency of the air to push the water toward the back of the pad. • Cleaning pump. Cleaning the pump is necessary once a year at startup. For your safety, disconnect from power source and unplug pump. Remove the pump from the mount bracket. Remove the base of the pump (Fig. 9). Clean the pump and turn the impeller to ensure free operation. Remove the pump spout and check for any blockage. After cleaning, reinstall the base onto the pump. Reattach the pump to the mount in the cooler to ensure that the pump will not overturn. Do not forget to replace the spout and water delivery tube onto the pump outlet. The pump has automatic reset thermal protection. Pump will operate normal again after obstruction is cleared. • Bleed off. Check bleed-off valve to be sure it is not clogged. Winter Shut Down • Drain water. Always drain all of the water out of the cooler and water supply line when not in use for prolonged periods, and particularly at the end of the season. Keep the water line disconnected from both the unit and water supply so that it does not freeze. • Disconnect from power supply when not in use for extended periods of time. • Cover unit. To protect the life of the finish, a cover for the unit is suggested in extended periods of non use. By following the operating, installation, and maintenance suggestions as outlined, you can get many years of efficient and satisfactory service from your cooler. In the event additional information is desired, your dealer will be more than glad to assist you in every possible way. 120 Volts Pump Wiring Diagrams 240 Volts Blue/BlackWhite Brown —• Orange —• Green Wire Nut - Pump - Com. >To Switch - Ground To Switch 110526 3 Troubleshooting Guide Problem Possible Cause Remedy Failure to 1. No electrical power 1. Check power start or no air to unit delivery • Fuse blown • Replace fuse • Circuit breaker tripped • Reset breaker 2. Belt too loose or tight 2. Adjust belt tension 3. Motor overheated 3. Determine cause of overheating • Belt too tight • Adjust belt tension • Blower bearings dry • Grease blower bear- ings • Motor bearings dry • Oil motor bearings • Motor pulley diameter • Adjust pulley to cor- too large rect diameter 4. Motor locked 4. Replace motor Inadequate 1. Insufficient air exhaust 1. Open windows or air delivery doors to increase air with cooler flow running 2. Belt too loose 2. Adjust belt tension or replace if needed 3. Pads plugged 3. Clean pads 4. Insufficient water flow 4. Clean distribution over pads system Musty or 1. Stale or stagnate water 1. Drain pan and clean unpleasant in cooler pads odor 2. Pads not wetting 2. Check water distribu- properly tion system • Dist. tube holes • Clean clogged • Pump not working • Replace or clean properly pump (Unplug) • Insufficient water flow • Clean water distribu- over pads tion system Problem Possible Cause Remedy Motor 1. Low voltage 1. Che...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - AD10012 (860.68 kb)
Ventilatoren - AD150 (860.68 kb)
Ventilatoren - AS100 (860.68 kb)
Ventilatoren - AS10012 (860.68 kb)