Anleitung Bosch, modell 8361 D

Hersteller: Bosch
Dateigröße: 342.38 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Technical Details Models Dimensions (in cm) Height Width Depth Maximum absorbed power Motor power Lighting Length of the cable Electrical connection 8160 D 80-135 59,8 47 170 W 1 x 155 W 1 x 11 W (PL) 150 cm 220-240 V 8190 D 82-137 89,8 48 170 W 1 x 155 W 1 x 11 W 150 cm 220-240 V 8260 D 80-135 59,8 47 200 W 1 x 155 W 2 x 20 W (G4) 150 cm 220-240 V 8290 D 82-137 89,8 48 200 W 1 x 155 W 2 x 20 W (G4) 150 cm 220-240 V 8360 D 80-135 59,8 47 175 W 1 x 130 W 2 x 20 W (G4) 150 cm 220-240 V 8390 D 82-137 89,8 48 175 W 1 x 130 W 2 x 20 W (G4) 150 cm 220-240 V 8361 D 80-135 59,8 47 175 W 1 x 130 W 2 x 20 W (G4) 150 cm 220-240 V 8391 D 82-137 89,8 48 175 W 1 x 130 W 2 x 20 W (G4) 150 cm 220-240 V Mounting accessories included 6 wall plugs O 8 mm (brick fixing only) 6 wood-screws 5 x 45 mm 2 metal screws 2,9 x 13 4 metal screws 2,9 x 6,5 5 metal screws 3,5 x 13 2 hooks 1 chimney support 2 clamps 1 deflector 1 reduction flange O 150-125 mm 1 charcoal filter frame 1 allen spanner Electrical connection (not for UK) Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access. Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board. When installing, an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided. Fixed connection of the appliance must only be carried out by an authorised electrician. Electrical connection for UK only Safety warnings for the electrician Connect the hood to the mains supply via a double pole switch which has 3 mm minimum separation between the contacts. The switch must be accessible at all times. The following is valid in the United Kingdom only: -the wire which is coloured green and yellow must be connected to the terminal which is marked with the letter E or by the earth symbol ( ), or coloured green or green and yellow; -the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black, - the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. Wall unit mounting - Fig. 7 • Position the template on the wall (1) and mark the position, and drill (2) the holes (2 x O 8 mm). • Mount the two wall plugs with the hooks (3). • Hang the hood on the hooks and level it with the adjustment screws (4). • Remove the grease filters (5) and mark for the two screws (6). Remove the hood and drill the holes (2 x O 8 mm). Insert the rawl plugs (7) and hang the hood on the wall again. Adjust it with the screws (8) and secure it with the screws (9). • Mount the chimney support (10) with the wall plugs (9) and the screws (11). Be careful that it is centered over the hood and horizontally aligned. • Ex...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - 8190 D (342.38 kb)
Ventilatoren - 8190 D (342.38 kb)
Ventilatoren - 8190 D (342.38 kb)
Ventilatoren - 8190 D (342.38 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien