|
Anleitung Zusammenfassung
OPTIONAL MAIN CONTROLS (only one main control can be installed on the system) 99-116 Dehumidistat Ventilation Control - Dehumidistat Dial, ON/OFF Switch and LOW/HIGH Switch (3 wire) 20 gauge wire (min.) 100' length (max.) Performance (HVI certified) Net supply air flow in cfm (L/s) against external static pressure E.S.P (external static pressure) [cfm (L/s)] @ 0.1" (25 Pa) 214 (101) @ 0.2" (50 Pa) 206 (97) @ 0.3" (75 Pa) 193 (91) @ 0.4" (100 Pa) 184 (87) @ 0.5" (125 Pa) 170 (80) @ 0.6" (150 Pa) 155 (73) @ 0.7" (175 Pa) 137 (65) Max. Temperature Recovery 69% Sensible Effectiveness @ 119 cfm (56 L/s) 32°F (0°C) 67% *Sensible Efficiency @ 119 cfm (56 L/s) 32°F (0°C) 60% *Sensible Efficiency @ 117 cfm (55 L/s) -13°F (-25°C) 60% VAC @ 60HZ 120 WATTS / Low speed. 70 WATTS / High speed 182 Amp rating 1.4 *Sensible Efficiency -thermal **Latent Efficiency -moisture 99-RECIRC Recirculation Control - Dehumidistat Dial, ON/OFF Switch and Recirculation Switch. Note: Effectiveness - based on temp. differential between the 2 airstreams The Recirculation Switch will toggle from continuous low speed ventilation to continuous Efficiency - takes into account all power inputs low speed recirculation. (4 wire) 20 gauge wire (min.) 100' length (max.) 99-130 Remote Dehumidistat - Dehumidistat Dial only. (2 wire) 20 gauge wire (min.) 100' length (max.) OPTIONAL TIMERS 99-132 20 Minute Fan Timer - initiates high speed ventilation for 20 minutes. (3 wire) 20 gauge wire (min.) 100’ length 99-104 Digital Electronic Timer- initiates high speed ventilation for 20, 40 or 60 minutes, (3 wire) 20 gauge wire (min.) 100' length 99-101 60 Minute Crank Timer -initiates high speed ventilation for up to 60 minutes, (2 wire) 20 gauge wire (min.) 100' length (max.) WARRANTY Units carry a lifetime warranty on the heat recovery core and a 5 year replacement parts warranty. 1 2 3 20 40 60 80 100 120 140 160 180 200 220 240 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Air Flow ( cfm) 3 - High Speed *2 - Medium Low Speed *1 - Low speed *Manufacturer’s data Static Pressure (in w.g.) All units conform to CSA and UL standards FRESH AIRDimensions FROM OUTSIDE RNC20 DEFROST STALE AIR DAMPER TO OUTSIDE inches (mm) DEFROST PORT BLOWERS FILTERS FRESH AIR STALE AIR TO INSIDE *NOTE: Front clearance of 25 inches (635 mm) is recommended for servicing unit. 19"(483) 14 3/4" (375) *All Duct Connections 6"(150mm) FROM INSIDE 33-5/8" BALANCING DAMPER CONDENSATE DRAINS Date: _______________________________________________ Contractor: __________________________________________ Tag: __________________________Qty:__________________ Supplier: ____________________________________________ Project: _____________________________________________ Quote#: _____________________________________________ Engineer:____________________________________________ Submitted by: ________________________________________ SP-RNC20 8 Engineering Data -HRV Model RNC5-TPD THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS Each air stream has an independent motorized impeller. 2 speed fan operation. FILTERS Washable air filters in exhaust and supply air streams. DEFROST Recirculating damper defrost system. CASE Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections 1/2" (12 mm) OD. MOUNTING THE HRV Four threaded inserts at corners of case designed to accept four reinforced polyester straps that are supplied with the unit. DUCT CONNECTIONS 4 - 5” (127 mm) duct connections. WEIGHT 61 lbs. (28 kg) SHIPPING WEIGHT 64 lbs. (29 kg) CONTROLS-HRV System Control HRV defaults to user selected speed from switch on top of cabinet when plugged in. HIGH SPEED option is accessible by connecting remote controls to designated terminals inside electrical box of HRV. OFF(Standby)/LOW or OFF/HIGH speed operation is also available. OPTIONAL MAIN CONTROLS (only one main control can be installed on the system) 99-116 Dehumidistat Ventilation Control - Dehumidistat Dial, ON/OFF Switch and Performance (H.V.I. certified) Net supply air flow in cfm (L/s) against external static pressure E.S.P (external static pressure) [cfm (L/s)] @ 0.1" (25 Pa) 169 (80) @ 0.2" (50 Pa) 156 (73) @ 0.3" (75 Pa) 149 (70) @ 0.4" (100 Pa) 136 (64) @ 0.5" (125 Pa) 126 (59) @ 0.6" (150 Pa) 116 (54) @ 0.7" (175 Pa) 103 (48) @ 0.8" (200 Pa) 89 (42) @ 0.9" (225 Pa) 77 (36) @ 1.0" (250 Pa) 58 (27) Max. Temperature Recovery 78% Sensible Effectiveness @ 66 cfm (31 L/s) 32°F (0°C) 74% *Sensible Efficiency @ 66 cfm (31 L/s) 32°F (0°C) 61% *Sensible Efficiency @ 76 cfm (36 L/s) -13°F (-25°C) 63% VAC @ 60HZ 120 WATTS / Low speed. 69 WATTS / High speed 147 Amp rating 1.7 *Sensible Efficiency -thermal **Latent Efficiency -moisture LOW/HIGH Switch (3 wire) 20 gauge wire (min.) 100' length (max.) Note: Effectiveness - based on temp. differential betwee...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - RNC10 (2.31 mb)
Ventilatoren - RNC120D (2.31 mb)
Ventilatoren - RNC20 (2.31 mb)
Ventilatoren - RNC200 (2.31 mb)