Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Hunter Fan, modell Saturn 90052

Hersteller: Hunter Fan
Dateigröße: 6.64 mb
Dateiname: 41718.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Screws are not provided. New Construction – suspended between joists Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Drill a hole in the center of each outline. Attach the rails onto the screws. 028_41718_EngS_1.28.08_Arial.indd 8 1/28/08 10:47:21 AM 41718-01 01/28/2008 9 Tighten screws. Pull wires through the strain relief. Connect wires as shown. B17 B18 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B19 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option B21 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. F G B20 028_41718_EngS_1.28.08_Arial.indd 9 1/28/08 10:47:24 AM 41718-01 01/28/2008 10 B27 E1 Go to step on page 17 to attach grille. B22 H Connect wiring from the motor to the wiring cover plate. H B23 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B25 Turn on the power source. ON OFF B26 Test the motor. If the motor does not run, check the plug connection. B24 I Secure the motor by tightening the 2 screws. 028_41718_EngS_1.28.08_Arial.indd 10 1/28/08 10:47:27 AM C12DEExisting Construction – accessible from above EXISTING FAN C11 NO EXISTING FAN 8”8.5” ORRemove an existing fan and check to make sure theopening is large enough to accommodate the newmotor housing (8”x 8.5”). Use the motor housing as a template to mark position. Cut out an opening for the housing. Slide the mounting rails into brackets. 5/81/25/81/2C13C14 position the correct depth mark at the bottom edge of the Mark position of screws by using holes as a template. joist based on the thickness of your sheetrock. 11 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 11 1/28/08 10:47:30 AM 41718-01 01/28/2008 12 C17 C18 C19 C20 C15 1/8” Bit C16 Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws. Tighten screws. Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Pull wires through the strain relief. 028_41718_EngS_1.28.08_Arial.indd 12 1/28/08 10:47:33 AM 41718-01 01/28/2008 13 C21 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground C22 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option Tighten the strain relief screws. Connect wires as shown. C24 H G F C23 Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring from the motor to the wiring cover plate. 028_41718_EngS_1.28.08_Arial.indd 13 1/28/08 10:47:35 AM 41718-01 01/28/2008 14 C25 H C26 I C27 ON OFF C28 Secure the motor by tightening the 2 screws. Turn on the power source. Test the motor. If the motor does not run, check the plug connection. C29 E1 Go to step on page 17 to attach grille. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 028_41718_EngS_1.28.08_Arial.indd 14 1/28/08 10:47:38 AM 41718-01 01/28/2008 15 D11 EXISTING FAN E D12 Existing Construction – accessible only from below D13 2 1 D14 Pull wires through strain relief. Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8.5”). Move the housing into position above the ceiling. Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. E D15 Screw pre-loaded screws into joist or framing. 028_41718_EngS_1.28.08_Arial.indd 15 1/28/08 10:47:40 AM 41718-01 01/28/2008 16 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground D16 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option H D18 H D19 D20 I Connect wires as shown. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Connect wiring from the motor to the wiring cover plate. Secure the motor by tightening the 2 screws. F D17 G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 028_41718_EngS_1.28.08_Arial.indd 16 1/28/08 10:47:43 AM 41718-01 01/28/2008 17 ON OFF D22 D23 E1 Go to step on page 17 to attach grille. D21 Test the motor. If the motor does not run, check the plug connection. Turn on the power source. Attaching the Grille Remove the thumbscrews. Connect wiring harness. M E E1 L E2 028_41718_EngS_1.28.08_Arial.indd 17 1/28/08 10:47:45 AM 41718-01 01...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - Saturn 90054 (6.64 mb)
Ventilatoren - Saturn 90058 (6.64 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien