|
Anleitung Zusammenfassung
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards, such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible. 7. Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit. 8. Install fan at least 5 feet (1.52 m) above the floor. 9. Never place a switch where it can be reached from a tub or shower. 10. This unit must be grounded. C A U T I O N Wa r n i n g DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT 1. For general ventilating use only. Do not use for ventilating hazardous or explosive materials. 2. To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward. 4. Please read specification label on product for further information and requirements. PREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan as listed below. TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders. TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. 41787-01 1/11/2006 2 x4 3/8" Cable Connector * * * NOTE: Strain relief cable connector must be installed. Not Included. A B C Extra Screws x2 H E D L 77864-02 F G H I J K 03242-07-133 96261-01-000 95047-02-000 74508-03-133 95776-01-000 75184-01-133 96258-01/02/03-008 75171-01/02/03-000 x2 Check all the parts. If damaged, call 1-888-830-1326 for replacements. x4 3/8" Cable Connector * * * NOTE: Strain relief cable connector must be installed. Not Included. A B C Extra Screws x2 H E D L 77864-02 F G H I J K 03242-07-133 96261-01-000 95047-02-000 74508-03-133 95776-01-000 75184-01-133 96258-01/02/03-008 75171-01/02/03-000 x2 Included. Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes Before Installation NOTE: Remove all packing materials before installation New construction installation Go to Step A1, page 4 Existing construction Go to Existing Construction Installation, page 8 Turn off the power source. 41787-01 1/11/2006 3 A1 D A2 A4 New Construction Installation A6 F A5 Loosen screw securing motor. Remove the motor/blower from the housing. A3 Remove packing material. Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover screw. 41787-01 1/11/2006 4 A8 D A9 B C A7 E A10 D 5/8 1/2 5/8 1/2 A11 OPTION Remove the wiring cover. Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Position the correct depth mark at the bottom edge of the joist–based on the thickness of your sheet rock. Screw pre-loaded screws into joist or framing. Nail the tabs on both sides to joist or framing so that the housing will be flush with the finished ceiling. (Nails are not provided.) 41787-01 1/11/2006 5 A13 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A14 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option A12 D E A15 F A016 D Pull the wires through the strain relief. Tighten the strain relief screws. Connect wires as shown. Connect a 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 41787-01 1/11/2006 6 A20 0 G D A18 0 D A17 G ...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - 41787-01 (4.63 mb)