Hersteller: Vermont Casting
Dateigröße: 882.07 kb
Dateiname:
|
Anleitung Zusammenfassung
Unpack the stove and carefully set it upright. CAUTION Porcelain enamelled surfaces are fragile. Handle porcelain enamelled castings tenderly. Familiarize yourself with the assembly steps before you begin and proceed with deliberation and care. If possible, have assistance available. Place enamelled castings on a soft, cushioned surface until you are ready to assemble. Avoid contact between the castings and other hard surfaces or objects. NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors sit flush on the gasket, and should lift easily from the seal around the opening. If you are not installing a fan, proceed to the appropriate vent assembly section. Install Optional Fan Kit #2960/FK28 Fan Kit Contents: • #10 x 1/2" phillips screws, 6 • Control Knob • Retainer Collar • Snapstat • Snapstat Bracket • Blower Assembly w/ Rheostat Control NOTE: The Rheostat Assembly and the Snapstat Assembly are not used on RF Models. For RF Models only: Follow Step 3, then run the spliced female leads to the front of the stove and attach to PC board of RF valve. Then follow Step 5. 1. Attach the Snapstat to the Bracket using two #10 x 1/2" phillips sheet metal screws as shown in Figure 12. 2. Locate and remove the 1/4-20 x 3/8" hex head bolt installed in the hole in the right rear ledge of the firebox. (Fig. 11) Use that bolt to secure the Snapstat Bracket to the firebox. The mounting hole is slotted to allow you to adjust the bracket so that its head makes contact with the firebox surface. (Fig. 11) 3. Attach the Fan to the firebox by engaging the upper flange of the fan skirt under the lower edge of the Shroud and secure the skirt with the four screws provided with the kit. (Figs. 12, 13) Fig. 11 Snapstat assembly and installation. Upper Flange ST241 ST240 Fig. 12 The upper flange of the fan skirt should be located behind the lower edge of the shroud. Fig. 13 Correct position of fan skirt installation. 4. The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 14) • Insert the switch box shaft through the hole in the back of the right side of the valve bracket, aligning the locator pin with the smaller hole in that bracket. • Attach the retaining nut to the switch control shaft to secure it to the plate. • Attach the Control Knob to the rheostat shaft. • Use the wire tie to secure the fan and rheostat wire harnesses together. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters Rheostat Retaining Nut Rheostat Knob FK104 Fig. 14 Attach rheostat to bracket. MOTOR SNAPSTAT ON/OFF RHEOSTAT WHT WHT BLKBLKBLK GRN BLK Blower Wiring Diagram Fan Assembly No. 000-2960 / FK28 WARNING: DISCONNECT ELECTRICAL SUPPLY BEFORE SERVICING Fig. 15 Blower wiring diagram. Venting System Assembly Direct Vent General Information The PDV20 and SDVR are approved for installation only with the vent components listed on Page 13. Follow the vent component instructions exactly. These instructions apply to both the PDV20 and the SDVR shell. 2. Locate the vent opening on the wall. Refer to Figures 17, 18 & 19 to determine the top of the opening centerline. It may be necessary to first position the stove and measure to find the hole location. Depending on whether the wall is made of combustible materials, cut the opening to the size shown in Figure 17. Combustible wall openings must be framed as shown in Figure 17. Sealant Phillips Screws ST396a Fig. 16 Apply sealant to the starter pipe, and fasten to stove with Phillips screws. 9..." (240mm) 10..." (265mm) 7..." Dia. (190mm) VO584-100 Fig. 17 Locate vent opening. Framing Detail Vent Opening - Combustible Wall Vent Opening -Noncombustible Wall For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 For Canadian installations: The venting system must conform to the current CSA B149.1 installation code. Rear Vent Use Rear Vent Kit 7TFSRSK for an installation where the heater is parallel to the wall and the vent system extends straight back through that wall. 1. Attach Inner Starter Pipe, (found in with the logset), to the stove. • Run a bead of sealant beneath the pipe bead and attach to the stove using three 1/4-20 x 3/8” phillips screws provided in the parts bag. (Fig. 16) 27..." (695mm) to Top of Opening Firestop Ventilated Wall Plate - Open End Down Finishing Collar Seal Around Terminal 9...” W x 10...” H Wall Opening ST400 Wall Sleeve - Seal Around Fig. 18 SDVR with Rear Vent Kit 7TFSRSK installation. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters 25..." (654mm) to Top of Opening Firestop Ventilated Wall Plate - Open End Down Finishing Collar Seal Around Terminal 9...” W x 10...” H Wall Opening ST400 Fig. 19 PDV20 with Rear Vent Kit 7TFSRSK installation. Wall Sleeve - Seal Around 3. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - 3926 (882.07 kb)
Ventilatoren - 3930 (882.07 kb)
Ventilatoren - 3936 (882.07 kb)
Ventilatoren - 3960 (882.07 kb)