Anleitung Zusammenfassung


When a contact is connected at DI 3, Al 3 is not available. Refer to AUX TEMP (Point15). DI 4 LOW TEMP DET 26 2299 Actual status of a contact connected to the controller. ON indicates that the contact is closed; OFF indicates that the contact is open. Actual status of the low temperature alarm, which is determined, by the current status of the low temperature detection thermostat. ON indicates that a low temperature has been detected. OFF indicates a normal condition. 26 2281, 2283, 2284, 2286, 2287 DX COOLING ELEC.NOELEC 27 2287 YES indicates a DX coil is used in cooling mode. NO indicates a chilled water valve is used in cooling mode. Valid input: YES or NO Indicates whether electric heating is being used. Valid input: ELEC or NOELEC 27 2281, 2283, 2284, 2286 FBP.2PSVCTL 28 2281, 2283, 2284, 2286 ENABLE allows two-position valves to close when the face- bypass damper has been closed (to full-bypass) for 2 minutes. DISABL disables the feature. Valid input: ENABLE or DISABL DAY.NGT 29 2281, 2283, 2284, 2286, 2287, 2299 Indicates the mode in which the controller is operating. Day temperature setpoints will be used in day mode. Night temperature setpoints will be used in night mode. This point is normally set by the field panel. WRMUP.COOLDN 30 2281, 2283, 2284, 2286, 2287 This point indicates whether or not the unit is currently in warmup/ cool-down. ON indicates the unit is in warm-up/cool down. OFF indicates the unit is not in warm-up/cool-down. Siemens Building Technologies, Inc. APOGEE Heat Pump Controller—Multi Stage Owner's Manual Descriptor Address Application Description AOV1SPAN 31 2281, 2283, 2284, 2286, 2287 Indicates the width of the voltage range where the actuator, controlled by AO1, moves. AOV1START 32 2281, 2283, 2284, 2286, 2287 Indicates the lower end of the voltage range where the actuator, controlled by AO1, moves. AOV2 SPAN 33 2281, 2283, 2284, 2286, 2287 Indicates the width of the voltage range where the actuator, controlled by AO2, moves. AOV2 START 34 2281, 2283, 2284, 2286, 2287 Indicates the lower end of the voltage range where the actuator, controlled by AO2, moves. AOV3 SPAN 35 2281, 2283, 2284, 2286, 2287 Indicates the width of the voltage range where the actuator, controlled by AO3, moves. AOV3 START 36 2281, 2283, 2284, 2286, 2287 Indicates the lower end of the voltage range where the actuator, controlled by AO3, moves. AO DIR.REV 37 2281, 2283, 2284, 2286, 2287 Masking point used to determine NO/NC status of actuators attached to analog outputs. AOV1 38 2281, 2283, 2284, 2286, 2287, 2299 Displays the voltage signal to AO1. AOV2 39 2281, 2283, 2284, 2286, 2287, 2299 Displays the voltage signal to AO2. AOV3 40 2281, 2283, 2284, 2286, 2287, 2299 Displays the voltage signal to AO3. DO 1 AUX RAD 41 2287, 2299 Digital output 1 controls a 24 Vac load with an ON or OFF status. The actual status of auxiliary radiation two-position actuator. 41 2281, 2283, 2284, 2286 DO 2 42 2281, 2283, 2284, 2286, 2287, 2299 Digital output 2 controls a 24 Vac load with an ON or OFF status. DO 3 43 2287, 2299 Digital output 3 controls a 24 Vac load with an ON or OFF status. HTG 2POS VLV 43 2281, 2283, 2284, 2286 The actual status of the two -position heating valve. DO 4 CLG 2POS VLV 44 2299 Digital output 4 controls a 24 Vac load with an ON or OFF status. The actual status of the two -position cooling valve. 44 2281, 2283 Siemens Building Technologies, Inc. Application 2299 – Slave Mode Descriptor Address Application Description DX 44 2284, 2286, 2287 The actual status of the DX cooling compressor. DO 5 EHEAT 1 45 2287, 2299 Digital output 5 controls a 24 Vac load with an ON or OFF status. The actual status of the first stage of electric heat. 45 2281, 2283, 2284, 2286 DO 6 EHEA T 2 46 2287, 2299 Digital output 6 controls a 24 Vac load with an ON or OFF status. The actual status of the second stage of electric heat. 46 2281, 2283, 2284, 2286 DO 7 EHEAT 3 47 2287, 2299 Digital output 7 controls a 24 Vac load with an ON or OFF status. The actual status of the third stage of electric heat. 47 2281, 2283, 2284, 2286 DO 8 FAN 50 2299 Digital output 8 controls a 24 Vac load with an ON or OFF status. This point is a digital output used to control the fan. ON indicates that the DO is energized; OFF indicates that the DO is de-energized. 50 2281, 2283, 2284, 2286, 2287 NGT HW HTG 53 2281, 2283, 2284, 2286, 2287 YES indicates that the heating valve will be kept open in night mode in both heating and cooling modes (recommended for systems with hot water). NO indicates heating valve will be controlled normally. Valid input: YES or NO NGT CLG MODE 54 2281, 2283, 2284, 2286, 2287 YES indicates that night cooling is available. NO indicates that night cooling is not available. Valid input: YES or NO AUX OUTPUT 55 2281, 2283, 2284, 2286 Indicates the percentage of time the auxiliary radiation will be ON. Valid values: 0 to 100% AUX HTG TIME 57 2281, 2283, 2284, 2286 The period of the auxiliary radiation pulse-width modu...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien