Anleitung Greenheck Fan, modell 471837
Hersteller: Greenheck Fan Dateigröße: 125.57 kb Dateiname: 0761f492-2e26-416e-a699-b7b93f7bab7c.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
(92mm) diameter hole in sleeve (Detail 2). 2) Attach indicator bracket to blade. For an airfoil blade dampers, use existing holes in blade (Detail 1-A). For a 3V blade damper, drill two 0.166 in. (4mm) holes (Detail 1-B). Fasten bracket to bladewith #10 x 1/2 in. (13mm) TEK screws (or equilavent). 3) Fit indicator link into blade bracket (Detail 1-C). 4) Insert TOR unit through hoel in sleeve (round end inside). 5) Place 4 in. x 4 in. J-box over the flange of the TOR unit and align holes. 6) Mount control box to sleeve/sideplate with #10-16 x3/4 in. (19mm) TEK screw or equilavent (Detail 1-D). 7) Place one pushnut on the switch wire. Place indicator link on switch wire and secure with a second pushnut (Detail 1-D). 8) Complete wiring and install J-box cover. Detail 1 TOR - Exploded View #10-16 x 3/4 in Upturned Leg Faces Away Fom Blade End #10 x 1/2 in. Tek Screw or Equivelant Part No. 415555 2 Req’d Indicator Bracket Part No. 658594 1 Req’d Airfoil Blade 3-V Blade Note: Indicator Link Part Nos For Standard Sleeve (short): 457808 For Extended Sleeve (long): 457801 Note: Operator Mounted Upside-Down On Steel Airfoil Units From 10 in. to 17 in. (254mm to 432mm) High ¡Detail 2~| Nominal Section Height (in.) 3V Style Steel Airfoil Style 6-7 2.625 2.625 8 3.125 3.125 9 3.625 3.625 10-11 2.625 3.625 12-13 2.625 4.125 14-15 3.125 4.625 16 3.625 5.125 17 4.125 5.625 18 13.125 13.125 19 14.125 14.125 20 14.625 14.625 21 15.625 15.625 22 16.625 16.625 23 17.125 17.125 24 18.125 18.125 25 19.625 19.625 26 20.625 20.625 27,39-41 21.625 21.625 28, 42 22.125 22.125 29, 43. 57 23.125 23.125 30, 44, 58 24.125 24.125 31, 45, 55-56, 59 25.125 25.125 32 26.625 26.625 33, 47 27.625 27.625 34, 46 28.625 28.625 35, 49 29.125 29.125 36, 48 30.625 30.625 37, 51 31.125 31.125 38, 50, 52 32.125 32.125 53 23.625 23.625 54 24.625 24.625 60 4.125 4.125 INSIDE SURFACE 8.375 3.563 < 11" NOM HEIGHT >11" NOM HEIGHT 03.625 All dimensions shown in inches. Wiring Diagram Temperature Limited Override and Open-Closed Indicator Note: The switch wires wrapped with a blue marker indicate the closed position of the damper. Electrical Capacity = 10 AMP (max) Yellow Optional Momentary Contact Test Switch L2 Electric Damper Actuator or Pneu. ^ Solenoid Valve |~ By Others ~| -*-9C£-d—-i- I <’vivk Damper | Indicator , Lights J r^GREENHECK P.O. Box 410 • Schofield, Wl 54476-0410 • 715.359.6171 ‘greenheck.ci Copyright © 2008 Greenheck Fan Corporation TOR Rev 1 July 2008 D...